Kochanek Krzysztof M, Śliwa Lech K, Puchacz Klaudia, Piłka Adam
Department of Experimental Audiology, Institute of Physiology and Pathology of Hearing, Warsaw, Poland.
Department of Logopedics and Applied Linguistics, Marie-Curie University, Lublin, Poland.
Med Sci Monit. 2015 Jan 4;21:36-43. doi: 10.12659/MSM.891365.
The aim of this study was to evaluate the repeatability and variability of TEOAE characteristics in hearing screening tests performed under practical conditions on normal subjects.
MATERIAL/METHODS: A group of 11 young, normal-hearing subjects aged 19-24 years was tested. They were examined otologically and audiologically prior to the tests and no ear pathologies were found. Responses were acquired with a commercially available instrument (Integrity, Vivosonic Inc.) using a standardized OAE protocol. The TEOAE tests were repeated 3 times in each subject at random intervals within 24 h. The analyzed parameters of interest were: (i) whole wave reproducibility (WWR) and; (ii) signal-to-noise ratio (SNR).
WWR and SNR did not differ significantly among the 3 measurement sessions. In most cases the differences in WWR among measurements were around 1-2% and for SNRs they were 1-4 dB SNRs and were highest in the 1-2 kHz range. TEOAE-based tests can be useful tools for hearing screening.
The tests can give reliable results provided that adequate procedures are used and low-noise conditions are ensured. The tests are best complemented with other examinations to widen the range of ear pathologies able to be detected.
本研究的目的是评估在实际条件下对正常受试者进行听力筛查测试时瞬态诱发耳声发射(TEOAE)特征的可重复性和变异性。
材料/方法:对一组11名年龄在19至24岁的听力正常的年轻受试者进行测试。在测试前对他们进行了耳科和听力学检查,未发现耳部病变。使用市售仪器(Integrity,Vivosonic公司)按照标准化的耳声发射协议采集反应。在24小时内随机间隔对每个受试者重复进行3次TEOAE测试。分析的感兴趣参数为:(i)全波重复性(WWR)和;(ii)信噪比(SNR)。
3次测量之间WWR和SNR无显著差异。在大多数情况下,测量之间WWR的差异约为1 - 2%,SNR的差异为1 - 4 dB SNR,在1 - 2 kHz范围内最高。基于TEOAE的测试可作为听力筛查的有用工具。
只要采用适当的程序并确保低噪声条件,这些测试就能给出可靠的结果。最好用其他检查来补充这些测试,以扩大能够检测到的耳部病变范围。