Suppr超能文献

Atherosclerotic neovasculature MR imaging with mixed manganese-gadolinium nanocolloids in hyperlipidemic rabbits.

作者信息

Wang Kezheng, Pan Dipanjan, Schmieder Anne H, Senpan Angana, Caruthers Shelton D, Cui Grace, Allen John S, Zhang Huiying, Shen Baozhong, Lanza Gregory M

机构信息

Department of Radiology, the Fourth Hospital of Harbin Medical University and Molecular Imaging Center of Harbin Medical University, Harbin, China; Division of Cardiology, Washington University School of Medicine, St. Louis, MO, USA.

Division of Cardiology, Washington University School of Medicine, St. Louis, MO, USA.

出版信息

Nanomedicine. 2015 Apr;11(3):569-78. doi: 10.1016/j.nano.2014.12.008. Epub 2015 Jan 31.

Abstract

A high r1 relaxivity manganese-gadolinium nanocolloid (αvβ3-MnOL-Gd NC) was developed and effectively detected atherosclerotic angiogenesis in rabbits fed cholesterol-rich diets for 12 months using a clinical MRI scanner (3T). 3D mapping of neovasculature signal intensity revealed the spatial coherence and intensity of plaque angiogenic expansion, which may, with other high risk MR bioindicators, help identify high-risk patients with moderate (40% to 60%) vascular stenosis. Microscopy confirmed the predominant media and plaque distribution of fluorescent αvβ3-MnOL-Gd NC, mirroring the MR data. An expected close spatial association of αvβ3-integrin neovasculature and macrophages was noted, particularly within plaque shoulder regions. Manganese oleate bioelimination occurred via the biliary system into feces. Gd-DOTA was eliminated through the bile-fecal and renal excretion routes. αvβ3-MnOL-Gd NC offers an effective vehicle for T1w neovascular imaging in atherosclerosis. From the clinical editor: Cerebrovascular accidents are a leading cause of mortality and morbidity worldwide. The acute formation of thrombus following atherosclerotic plaque rupture has been well recognized as the etiology of stroke. The authors studied microanatomical features of vulnerable atherosclerotic plaque in this article, in an attempt to identify those with high risk of rupture. Gadolinium-manganese hybrid nanocolloid (MnOL-Gd NC) was developed as a novel contrast agent for MRI. They show that this agent is effective in providing neovascular imaging.

摘要

相似文献

1
Atherosclerotic neovasculature MR imaging with mixed manganese-gadolinium nanocolloids in hyperlipidemic rabbits.
Nanomedicine. 2015 Apr;11(3):569-78. doi: 10.1016/j.nano.2014.12.008. Epub 2015 Jan 31.
3
Microdistribution of Magnetic Resonance Imaging Contrast Agents in Atherosclerotic Plaques Determined by LA-ICP-MS and SR-μXRF Imaging.
Mol Imaging Biol. 2021 Jun;23(3):382-393. doi: 10.1007/s11307-020-01563-z. Epub 2020 Dec 7.
4
Molecular MR imaging of neovascular progression in the Vx2 tumor with αvβ3-targeted paramagnetic nanoparticles.
Radiology. 2013 Aug;268(2):470-80. doi: 10.1148/radiol.13120789. Epub 2013 Jun 14.
5
Molecular and cellular targets of the MRI contrast agent P947 for atherosclerosis imaging.
Mol Pharm. 2012 Apr 2;9(4):850-61. doi: 10.1021/mp2003863. Epub 2012 Mar 8.
6
Molecular imaging of angiogenesis in early-stage atherosclerosis with alpha(v)beta3-integrin-targeted nanoparticles.
Circulation. 2003 Nov 4;108(18):2270-4. doi: 10.1161/01.CIR.0000093185.16083.95. Epub 2003 Oct 13.
7
Multifunctional Gadolinium-Doped Manganese Carbonate Nanoparticles for Targeted MR/Fluorescence Imaging of Tiny Brain Gliomas.
Anal Chem. 2015 Jun 16;87(12):6251-7. doi: 10.1021/acs.analchem.5b01639. Epub 2015 Jun 2.
8
Contrast-enhanced ultrasound imaging detects intraplaque neovascularization in an experimental model of atherosclerosis.
JACC Cardiovasc Imaging. 2010 Dec;3(12):1256-64. doi: 10.1016/j.jcmg.2010.09.017.
10
64Cu-Labeled Divalent Cystine Knot Peptide for Imaging Carotid Atherosclerotic Plaques.
J Nucl Med. 2015 Jun;56(6):939-44. doi: 10.2967/jnumed.115.155176. Epub 2015 Apr 23.

本文引用的文献

2
Heart disease and stroke statistics--2013 update: a report from the American Heart Association.
Circulation. 2013 Jan 1;127(1):e6-e245. doi: 10.1161/CIR.0b013e31828124ad. Epub 2012 Dec 12.
4
Heart disease and stroke statistics--2012 update: a report from the American Heart Association.
Circulation. 2012 Jan 3;125(1):e2-e220. doi: 10.1161/CIR.0b013e31823ac046. Epub 2011 Dec 15.
5
Polydisulfide manganese(II) complexes as non-gadolinium biodegradable macromolecular MRI contrast agents.
J Magn Reson Imaging. 2012 Mar;35(3):737-44. doi: 10.1002/jmri.22848. Epub 2011 Oct 26.
7
Molecular photoacoustic imaging of angiogenesis with integrin-targeted gold nanobeacons.
FASEB J. 2011 Mar;25(3):875-82. doi: 10.1096/fj.10-171728. Epub 2010 Nov 19.
8
Variable antibody-dependent activation of complement by functionalized phospholipid nanoparticle surfaces.
J Biol Chem. 2011 Jan 7;286(1):123-30. doi: 10.1074/jbc.M110.180760. Epub 2010 Nov 3.
9
Revisiting an old friend: manganese-based MRI contrast agents.
Wiley Interdiscip Rev Nanomed Nanobiotechnol. 2011 Mar-Apr;3(2):162-73. doi: 10.1002/wnan.116. Epub 2010 Sep 21.
10
Simultaneous dual frequency 1H and 19F open coil imaging of arthritic rabbit knee at 3T.
IEEE Trans Med Imaging. 2011 Jan;30(1):22-7. doi: 10.1109/TMI.2010.2056689. Epub 2010 Aug 9.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验