Baumgartner Stefan, Iliadi Anna, Eliades Theodore, Eliades George
Prog Orthod. 2015 Feb 10;16:1. doi: 10.1186/s40510-014-0071-8.
The aim of the present study was to assess the changes in enamel roughness parameters before and after stripping with an oscillating diamond strip system.
Sound premolars extracted for orthodontic reasons were embedded up to their cervical area in a polyvinylsiloxane putty, creating four groups of four teeth with three interproximal areas each (mesial/distal). The same regions of interproximal enamel surfaces were studied by 3D optical interferometric profilometry before and after stripping with the Ortho-Strips system (Intensiv Dental SA, Montagnola, Switzerland) (n teeth = 16, n contact points = 12, n sites measured = 24). The roughness parameters tested were the amplitude parameters Sa and Sz, the hybrid parameter Sdr, and the functional parameters Sci and Svi. The parameter differences (ΔSa, ΔSz, ΔSdr, ΔSci, ΔSvi) were calculated per region and statistically analyzed by one-sample Mann-Whitney rank sum test (a = 0.05).
High statistically significant differences were found in ΔSa, ΔSz, and ΔSvi median values (0.453, 3.870, and 0.040 μm, respectively); a significant difference in ΔSdr median value (1.514%); and no statistically significant difference in ΔSci (0.110 median value).
Under the conditions of the present study, the Ortho-Strips system seems to significantly increase the amplitude parameters Sa and Sz; the hybrid parameter Sdr, associated with the developed interfacial area ratio; and the functional parameter Svi, which depicts the volume of the deepest valleys. Under the conditions of the present study, the Ortho-Strips seems to significantly increase four of five measured roughness parameters.
本研究的目的是评估使用振荡式金刚石条系统进行酸蚀处理前后牙釉质粗糙度参数的变化。
因正畸原因拔除的健康前磨牙,将其颈部区域埋入聚乙烯基硅氧烷油灰中,形成四组,每组四颗牙齿,每个牙齿有三个邻面区域(近中/远中)。使用Ortho-Strips系统(Intensiv Dental SA,瑞士蒙塔尼奥拉)对邻面牙釉质表面的相同区域进行酸蚀处理前后,通过三维光学干涉轮廓术进行研究(n牙齿=16,n接触点=12,n测量部位=24)。测试的粗糙度参数包括幅度参数Sa和Sz、混合参数Sdr以及功能参数Sci和Svi。计算每个区域的参数差异(ΔSa、ΔSz、ΔSdr、ΔSci、ΔSvi),并通过单样本曼-惠特尼秩和检验进行统计学分析(α=0.05)。
在ΔSa、ΔSz和ΔSvi的中位数中发现了高度统计学显著差异(分别为0.453、3.870和0.040μm);ΔSdr中位数有显著差异(1.514%);而ΔSci中位数无统计学显著差异(0.110)。
在本研究条件下,Ortho-Strips系统似乎能显著增加幅度参数Sa和Sz;与界面面积比相关的混合参数Sdr;以及描述最深谷体积的功能参数Svi。在本研究条件下,Ortho-Strips似乎能显著增加所测量的五个粗糙度参数中的四个。