Ibarz Marta, Hernández-Verdejo José Luis, Bolívar Gema, Tañá Pedro, Rodríguez-Prats José Luis, Teus Miguel A
a Hospital Moncloa, Oftalvist Madrid , Madrid , Spain .
b VISSUM Madrid , Madrid , Spain .
Curr Eye Res. 2016 Apr;41(4):507-12. doi: 10.3109/02713683.2015.1023459. Epub 2015 May 27.
To investigate the changes in intraocular pressure (IOP) in porcine eyes during femtosecond laser-assisted cataract surgery using a liquid-optic interface system.
Femtosecond laser cataract surgery with the Catalys™ was performed on freshly enucleated porcine eyes in Oftalvist Moncloa, Madrid, Spain. Capsulorhexis and lens fragmentation were completed in all the eyes without complications. IOP was measured with a reusable blood pressure transducer connected by direct cannulation to the anterior chamber, recording data before suction (basal), at the beginning of the suction phase, every five seconds during femtosecond procedure and after the removal of the suction ring from the eye.
Nine porcine eyes were used in this study. Basal IOP before suction was 5.67 ± 2.39 mmHg, rising to 20.33 ± 4.18 mmHg at the beginning of the suction phase (p < 0.001). During femtosecond procedure, pressure reached a value of 19.74 ± 4.31 mmHg, remaining stable during the entire process. The IOP recorded prior to removal of the suction ring was 21.00 ± 6.93 mmHg, returning to basal values in all the eyes after the suction ring was removed, with no statistical differences between basal and post-suction IOPs. Total femtosecond procedure time was 125.9 ± 15.9 s.
Real-time IOP can be measured during surgery using a transducer connected to the anterior chamber. The results showed a significant increase in IOP during the procedure due to the pressure exerted by the suction ring but not by the effect of the femtosecond laser.
研究使用液体光学界面系统的飞秒激光辅助白内障手术过程中猪眼眼压(IOP)的变化。
在西班牙马德里的奥塔尔维斯·蒙克洛亚,对新鲜摘除的猪眼进行了使用Catalys™的飞秒激光白内障手术。所有眼睛均顺利完成撕囊和晶状体破碎,无并发症。通过直接插管将可重复使用的血压传感器连接至前房来测量眼压,记录抽吸前(基础值)、抽吸阶段开始时、飞秒手术过程中每5秒以及从眼中取出抽吸环后的眼压数据。
本研究使用了9只猪眼。抽吸前基础眼压为5.67±2.39 mmHg,在抽吸阶段开始时升至20.33±4.18 mmHg(p<0.001)。在飞秒手术过程中,眼压达到19.74±4.31 mmHg,并在整个过程中保持稳定。取出抽吸环前记录的眼压为21.00±6.93 mmHg,取出抽吸环后所有眼睛的眼压均恢复至基础值,基础眼压与抽吸后眼压之间无统计学差异。飞秒手术总时间为125.9±15.9秒。
手术过程中可使用连接至前房的传感器测量实时眼压。结果显示,手术过程中眼压因抽吸环施加的压力而显著升高,而非飞秒激光的作用。