Öztürk Elif, Güder Gizem
Department of Restorative Dentistry, Hacettepe University, Faculty of Dentistry, Sihhiye, Ankara, Turkey.
Department of Restorative Dentistry, Kocaeli University, Faculty of Dentistry, Yuvacik/Basiskele, Kocaeli, Turkey.
Scanning. 2015 Nov-Dec;37(6):438-45. doi: 10.1002/sca.21233. Epub 2015 Jun 30.
The aim of this study was to evaluate the 3-dimensional (3D) surface topography and color stability of four different resin composites after immersion in different soft-beverages.
One hundred sixty disk-shaped specimens (diameter: 10 mm, and thickness: 2 mm) were made from four different resin composites (i.e., Filtek Z550, Tetric N-Ceram, Clearfil Majesty Esthetic, and Cavex Quadrant Universal LC). Each specimen was cured under mylar strips for 20 sec for both top and bottom surfaces. All of the specimens were stored in distilled water for 24 h at 37°C. Surface measurements were carried out using a noncontact 3D-optical-profilometer in terms of surface topography (Ra values). Color measurements of each specimen were performed with Vita Easy Shade system. All the measurements were performed at baseline and after 30 days of immersion in the selected soft-beverages (Redbull, Coca-Cola and Dimes-Lemonade). Control groups were stored in distilled water during the study. Ra values and color changes (ΔE values) of the groups were recorded. The data were statistically analyzed using a one way ANOVA and Tukey's post-hoc tests (SPSS 18.0).
The tested soft-beverages in the present study caused color changes at a 30-day evaluation period for the tested resin composites (p < 0.05). However, 3D surface topography of resin composites was not influenced by the tested soft-beverages (p > 0.05). There was no significant interaction between the composite and beverage type on the Ra values of the resin composites (p > 0.05).
No correlation was found between color stability and 3D surface topography of the resin composites. Color stability of resin composites may be affected by soft beverages.
本研究旨在评估四种不同树脂复合材料在浸入不同软饮料后其三维(3D)表面形貌及颜色稳定性。
用四种不同的树脂复合材料(即Filtek Z550、Tetric N-Ceram、Clearfil Majesty Esthetic和Cavex Quadrant Universal LC)制作160个圆盘形试件(直径:10毫米,厚度:2毫米)。每个试件的顶面和底面在聚酯薄膜条下固化20秒。所有试件在37°C的蒸馏水中储存24小时。使用非接触式三维光学轮廓仪进行表面形貌(Ra值)测量。用Vita Easy Shade系统对每个试件进行颜色测量。所有测量均在基线时以及浸入所选软饮料(红牛、可口可乐和芬达柠檬水)30天后进行。对照组在研究期间储存在蒸馏水中。记录各组的Ra值和颜色变化(ΔE值)。使用单因素方差分析和Tukey事后检验(SPSS 18.0)对数据进行统计学分析。
本研究中测试的软饮料在30天评估期内导致测试树脂复合材料发生颜色变化(p < 0.05)。然而,树脂复合材料的三维表面形貌不受测试软饮料的影响(p > 0.05)。树脂复合材料的Ra值在复合材料和饮料类型之间没有显著相互作用(p > 0.05)。
未发现树脂复合材料的颜色稳定性与三维表面形貌之间存在相关性。树脂复合材料的颜色稳定性可能受软饮料影响。