Emerson Roger H, Barrington John W, Olugbode Seun A, Alnachoukati Omar K
Texas Center for Joint Replacement, Plano, Texas.
Plano Orthopedic Sports Medicine & Spine Center, Plano, Texas.
J Arthroplasty. 2016 Feb;31(2):425-8. doi: 10.1016/j.arth.2015.09.032. Epub 2015 Sep 28.
Frequently, a normal posterior-cruciate ligament (PCL) is removed at the surgeon's discretion, converting the normal 4-ligament knee to a 2-ligament knee, thus eliminating the need to balance all 4 ligaments. The development of modular tibial components has led to the availability of differing polyethylene inserts that permit adjustment to the flexion gap independent of the extension gap, permitting PCL balancing not previously available. The purpose of this study is to analyze a specific cruciate-retaining (CR) prosthesis which has 2 polyethylene inserts intended for CR knee use.
Between February 2004 and February 2013, the senior author (R.H.E.) has performed 930 total knee arthroplasties using the CR flat insert and 424 knees using the CR lipped insert. The inserts were selected during surgery, based on the assessed tension and function of the PCL. The patients were followed up as part of a prospective total joint program with the Knee Society clinical scoring, range of motion, complications, revisions, preoperative coronal deformity, gender, body mass index, and status of the anterior-cruciate ligament intraoperatively.
The average Knee Score was 92.4 for the flat group and 92.1 for the lipped group. Average knee flexion was 116.2° for the flat group and 114.4° for the lipped group (P=.2). Average knee extension (flexion deformity) was 2.1° for the flat group and 0.9° for the lipped group
The results reported here show that clinical outcomes and survivorship were no different for either insert option, leading to indirect evidence that appropriate soft tissue balance had been achieved.
通常情况下,外科医生可自行决定切除正常的后交叉韧带(PCL),将正常的四韧带膝关节转变为双韧带膝关节,从而无需平衡所有四条韧带。模块化胫骨组件的发展使得不同的聚乙烯衬垫可供使用,这些衬垫可独立于伸直间隙调整屈曲间隙,实现了此前无法做到的PCL平衡。本研究的目的是分析一种特定的保留交叉韧带(CR)假体,该假体有两个用于CR膝关节的聚乙烯衬垫。
在2004年2月至2013年2月期间,资深作者(R.H.E.)使用CR平衬垫进行了930例全膝关节置换术,使用CR唇形衬垫进行了424例膝关节置换术。手术过程中根据评估的PCL张力和功能选择衬垫。作为前瞻性全关节项目的一部分,对患者进行随访,记录膝关节协会临床评分、活动范围、并发症、翻修情况、术前冠状面畸形、性别、体重指数以及术中前交叉韧带的状况。
平衬垫组的平均膝关节评分为92.4分,唇形衬垫组为92.1分。平衬垫组的平均膝关节屈曲角度为116.2°,唇形衬垫组为114.4°(P = 0.2)。平衬垫组的平均膝关节伸直(屈曲畸形)角度为2.1°,唇形衬垫组为0.9°。
此处报告的结果表明,两种衬垫选择的临床结果和生存率并无差异,间接证明已实现了适当的软组织平衡。