Reichstein E, Morton R C, Diamandis E P
CyberFluor, Inc., Toronto, Ontario, Canada.
Clin Biochem. 1989 Feb;22(1):23-9. doi: 10.1016/s0009-9120(89)80065-7.
We have developed a time-resolved solid-phase immunofluorometric assay for thyrotropin (TSH). The assay is performed in white opaque microtitration wells which are coated with a monoclonal capture antibody. Serum TSH binds simultaneously to the solid phase and to a biotinylated monoclonal detection antibody. The degree of biotinylated antibody binding is quantitated with streptavidin conjugated to thyroglobulin which is heavily labelled with the Eu3+ chelator 4,7-bis [chlorosulfophenyl] -1,10-phenanthroline -2,9-dicarboxylic acid (BCPDA). The final fluorescent complex is measured on the solid phase with time-resolved fluorometry. The assay requires two incubation steps and can be completed in 5 hours. The detection limit is 0.03 milli-int. units/L. The present assay was compared with two immunoradiometric assays and gave satisfactory results.
我们已开发出一种用于促甲状腺激素(TSH)的时间分辨固相免疫荧光测定法。该测定法在涂有单克隆捕获抗体的白色不透明微量滴定孔中进行。血清TSH同时与固相和生物素化的单克隆检测抗体结合。生物素化抗体的结合程度用与甲状腺球蛋白缀合的链霉亲和素进行定量,该甲状腺球蛋白用铕(Eu3+)螯合剂4,7-双[氯磺苯基]-1,10-菲咯啉-2,9-二羧酸(BCPDA)进行了大量标记。最终的荧光复合物通过时间分辨荧光法在固相上进行测量。该测定法需要两个孵育步骤,可在5小时内完成。检测限为0.03毫国际单位/升。将本测定法与两种免疫放射测定法进行了比较,结果令人满意。