Suppr超能文献

评估一种附聚合瓣阀输尿管支架在膀胱内压升高情况下预防膀胱输尿管反流的效果:一项使用猪模型的初步研究。

Evaluation of a Polymeric Flap Valve-Attached Ureteral Stent for Preventing Vesicoureteral Reflux in Elevated Intravesical Pressure Conditions: A Pilot Study Using a Porcine Model.

作者信息

Kim Hyeon Woo, Park Chang-Ju, Seo Seungwan, Park Yangkyu, Lee Jeong Zoo, Shin Dong Gil, Moon Hong Sang, Lee Jong-Hyun

机构信息

1 Department of Medical System Engineering, Gwangju Institute of Science and Technology (GIST) , Gwangju, South Korea .

2 School of Mechatronics, Gwangju Institute of Science and Technology (GIST) , Gwangju, South Korea .

出版信息

J Endourol. 2016 Apr;30(4):428-32. doi: 10.1089/end.2015.0711. Epub 2015 Dec 17.

Abstract

OBJECTIVE

To evaluate the effectiveness of a polymeric flap valve-attached ureteral stent for preventing vesicoureteral reflux (VUR) in an animal model.

MATERIALS AND METHODS

One female Yorkshire pig was included in this study. A flap valve-attached and a conventional stent was inserted in the right and left ureters, respectively. The bladder was filled with contrast medium until the intravesical pressure reached 20 cm H2O. Subsequently, simulated voiding cystourethrography (VCUG) was performed 50 times by manually compressing the suprapubic area until the intravesical pressure reached 50 cm H2O. Intravenous pyelography (IVP) was performed thereafter to evaluate the urinary drainage. In addition, an in vitro durability test of the function of the flap valve was conducted under continuous hydrostatic pressure for 24 h.

RESULTS

The volume of contrast medium needed to achieve an intravesical pressure of 20 cm H2O was 1740 mL. In the repeated simulated VCUG for the right ureter, VUR grades of 0 and I were recorded in 82.0 (n = 41) and 18.0% (n = 9) tests, respectively, whereas for the left ureter, grades of I, II, and III were recorded in 14.0 (n = 7), 82.0 (n = 41), and 4.0% (n = 2), respectively. Thus, a significantly lower VUR grade was recorded for the right ureter than for the left ureter (p < 0.001). In the bilateral VUR condition, the pressure for VUR occurrence was significantly greater in the right ureter than in the left ureter (p = 0.007). No urinary obstruction was caused by the flap valve-attached ureteral stent according to the IVP findings. The in vitro durability test demonstrated slightly enhanced antireflux function and slightly decreased intraluminal drainage at 12 h, and these findings sustained thereafter.

CONCLUSION

A flap valve-attached ureteral stent effectively prevented VUR under conditions of elevated intravesical pressure without urinary obstruction.

摘要

目的

在动物模型中评估附有聚合物瓣阀的输尿管支架预防膀胱输尿管反流(VUR)的有效性。

材料与方法

本研究纳入1只雌性约克夏猪。分别在右侧和左侧输尿管中插入附有瓣阀的支架和传统支架。向膀胱内注入造影剂,直至膀胱内压力达到20 cm H₂O。随后,通过手动按压耻骨上区域进行50次模拟排尿性膀胱尿道造影(VCUG),直至膀胱内压力达到50 cm H₂O。之后进行静脉肾盂造影(IVP)以评估尿液引流情况。此外,在持续静水压力下对瓣阀功能进行24小时的体外耐久性测试。

结果

达到20 cm H₂O膀胱内压力所需的造影剂体积为1740 mL。在右侧输尿管的重复模拟VCUG中,0级和I级VUR分别在82.0%(n = 41)和18.0%(n = 9)的测试中记录到,而左侧输尿管中,I级、II级和III级分别在14.0%(n = 7)、82.0%(n = 41)和4.0%(n = 2)的测试中记录到。因此,右侧输尿管记录到的VUR分级显著低于左侧输尿管(p < 0.001)。在双侧VUR情况下,右侧输尿管发生VUR的压力显著高于左侧输尿管(p = 0.007)。根据IVP结果,附有瓣阀的输尿管支架未引起尿路梗阻。体外耐久性测试表明,在12小时时抗反流功能略有增强,管腔内引流略有减少,此后这些结果持续存在。

结论

附有瓣阀的输尿管支架在膀胱内压力升高的情况下能有效预防VUR且不会引起尿路梗阻。