Suppr超能文献

[Effect of Reconstruction Technique for Metal Artifact Reduction in Computed Tomography by Changing Display Field of View].

作者信息

Nakamura Shinobu, Kawata Hidemichi, Kuroki Hidefumi, Mizoguchi Asumi

机构信息

Daignostic Imaging Center, Kurume University Hospital.

出版信息

Nihon Hoshasen Gijutsu Gakkai Zasshi. 2015 Nov;71(11):1096-102. doi: 10.6009/jjrt.2015_JSRT_71.11.1096.

Abstract

We evaluated the effect of orthopedic-metal artifact reduction (O-MAR) for metal artifact in computed tomography with 73 simulated seeds for brachytherapy in different sizes of display field of view (DFOV) obtained by helical scan under the same clinical scan condition. The metal artifacts were analyzed with the Gumbel's method by changing DFOV sizes 80 mm, 160 mm, and 320 mm. Gumbel distribution, scale parameter (γ), and location parameter (β) of the metal artifacts with O-MAR were compared with that of the metal artifacts with filtered back projection (FBP). In conclusion, it was considered that the effect of metal artifact reduction with O-MAR was influenced by DFOV size in this study. The reduction rates of scale parameter (γ) were 22.3%, 21.3%, and 10.0% in DFOV 80 mm, 160 mm, and 320 mm, respectively. The reduction rates of location parameter (β) were 27.4%, 23.4 %, and 9.8%. Therefore, the effect of metal artifact reduction with O-MAR showed the tendency of increasing with decreasing DFOV size.

摘要

相似文献

1
[Effect of Reconstruction Technique for Metal Artifact Reduction in Computed Tomography by Changing Display Field of View].
Nihon Hoshasen Gijutsu Gakkai Zasshi. 2015 Nov;71(11):1096-102. doi: 10.6009/jjrt.2015_JSRT_71.11.1096.
4
Normalized metal artifact reduction in head and neck computed tomography.
Invest Radiol. 2012 Jul;47(7):415-21. doi: 10.1097/RLI.0b013e3182532f17.
5
Metal Artifact Reduction for Orthopedic Implants (O-MAR): Usefulness in CT Evaluation of Reverse Total Shoulder Arthroplasty.
AJR Am J Roentgenol. 2017 Oct;209(4):860-866. doi: 10.2214/AJR.16.17684. Epub 2017 Aug 10.
6
Influence of field of view size and reconstruction methods on single-energy metal artifact reduction: a phantom study.
Phys Eng Sci Med. 2022 Jun;45(2):637-642. doi: 10.1007/s13246-022-01130-6. Epub 2022 May 20.
7
Model-Based Iterative Reconstruction (MBIR) for the Reduction of Metal Artifacts on CT.
AJR Am J Roentgenol. 2015 Aug;205(2):380-5. doi: 10.2214/AJR.14.13334.
8
Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation.
Korean J Radiol. 2017 May-Jun;18(3):526-535. doi: 10.3348/kjr.2017.18.3.526. Epub 2017 Apr 3.
9
[Application of Hamiltonian Monte Carlo Method to Metal Artifact Quantitative Evaluation in Computed Tomography (CT)].
Nihon Hoshasen Gijutsu Gakkai Zasshi. 2017;73(8):654-663. doi: 10.6009/jjrt.2017_JSRT_73.8.654.
10
Metal artifact reduction in MRI-based cervical cancer intracavitary brachytherapy.
Phys Med Biol. 2017 Apr 21;62(8):3011-3024. doi: 10.1088/1361-6560/62/8/3011. Epub 2017 Mar 17.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验