Suppr超能文献

身体摇摆中心在电刺激下的偏差。

The deviation of the body's sway center with galvanic stimulation.

作者信息

Ito K, Wada K, Miyasita Y, Taguchi K

机构信息

Department of Otolaryngology, Shinshu University School of Medicine, Matsumoto, Japan.

出版信息

Auris Nasus Larynx. 1989;16(1):23-32. doi: 10.1016/s0385-8146(89)80004-5.

Abstract

We investigated galvanic body sway of ten healthy adults and eight patients by using the averaging program for measuring T1 and T2, which were latencies at the onset and at the cutoff of galvanic stimulation, respectively, and the plotting program, which adopted 1.73 sec as T1 and 0.39 sec as T2, for calculating the coordinates of the body's sway center. We estimated galvanic body sway with the difference between the coordinate of the body's sway center during stimulation and that during no stimulation. The deviation in lateral direction on the healthy subjects ranged from 0.7 or 0.9 to 2.1 cm at right- or left-side stimulation. One of the patients with peripheral disorders revealed differences between right- and left-side stimulation. The other patients did not reveal any differences. In antero-posterior direction six of the healthy subjects deviated backward at right-side stimulation and nine subjects deviated backward at left-side stimulation. The patients with peripheral disorders did not reveal any differences. The other patients revealed some differences. Waves computed by the averaging program do not always show the quantity of galvanic body sway. The deviation of the body's sway center shows the quantity of body sway consistently. The body's sway center is considered to be a suitable parameter in the galvanic body sway test for statistical analysis.

摘要

我们通过使用平均程序来测量T1和T2(分别为电刺激开始和结束时的潜伏期)以及绘图程序(该程序采用1.73秒作为T1,0.39秒作为T2)来计算身体摆动中心的坐标,对10名健康成年人和8名患者的电刺激身体摆动进行了研究。我们通过刺激期间身体摆动中心的坐标与无刺激期间身体摆动中心的坐标之间的差异来估计电刺激身体摆动。健康受试者在右侧或左侧刺激时,横向偏差范围为0.7或0.9至2.1厘米。一名患有周围性疾病的患者在右侧和左侧刺激之间存在差异。其他患者未显示出任何差异。在前后方向上,6名健康受试者在右侧刺激时向后偏离,9名受试者在左侧刺激时向后偏离。患有周围性疾病的患者未显示出任何差异。其他患者显示出一些差异。通过平均程序计算出的波形并不总是能显示电刺激身体摆动的量。身体摆动中心的偏差始终显示身体摆动的量。身体摆动中心被认为是电刺激身体摆动测试中进行统计分析的合适参数。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验