Distal ulnar nerve injury leads to impairment of hand function due to motor and sensorial changes. Stimulus electrodiagnosis (SE) is a method of assessing and monitoring the development of this type of injury.
To identify the most sensitive electrodiagnostic parameters to evaluate ulnar nerve recovery and to correlate these parameters (Rheobase, Chronaxie, and Accommodation) with motor function evaluations.
A prospective cohort study of ten patients submitted to ulnar neurorrhaphy and evaluated using electrodiagnosis and motor assessment at two moments of neural recovery. A functional evaluation using the DASH questionnaire (Disability of the Arm, Shoulder, and Hand) was conducted at the end to establish the functional status of the upper limb.
There was significant reduction only in the Chronaxie values in relation to time of injury and side (with and without lesion), as well as significant correlation of Chronaxie with the motor domain score.
Chronaxie was the most sensitive SE parameter for detecting differences in neuromuscular responses during the ulnar nerve recovery process and it was the only parameter correlated with the motor assessment.
尺神经损伤会导致手部运动和感觉功能障碍。刺激电诊断(SE)是评估和监测此类损伤发展的一种方法。
确定评估尺神经恢复最敏感的电诊断参数,并将这些参数(阈值、弛豫时间和顺应性)与运动功能评估相关联。
对 10 例接受尺神经吻合术的患者进行前瞻性队列研究,在神经恢复的两个时间点使用电诊断和运动评估进行评估。在最后使用 DASH 问卷(手臂、肩部和手部残疾)进行功能评估,以确定上肢的功能状态。
仅在损伤时间和侧别(有和无病变)方面,Chronaxie 值显著降低,Chronaxie 与运动域评分显著相关。
Chronaxie 是检测尺神经恢复过程中神经肌肉反应差异最敏感的 SE 参数,也是唯一与运动评估相关的参数。