红外眼热成像技术在评估健康眼和干眼方面的可重复性。

Repeatability of infrared ocular thermography in assessing healthy and dry eyes.

作者信息

Tan Li Li, Sanjay Srinivasan, Morgan Philip B

机构信息

School of Chemical and Life Sciences, Singapore Polytechnic, Singapore.

Ophthalmology and Visual Sciences, Khoo Teck Puat Hospital, Singapore; Yong Loo Lin School of Medicine, National University of Singapore, Singapore.

出版信息

Cont Lens Anterior Eye. 2016 Aug;39(4):284-92. doi: 10.1016/j.clae.2016.01.010. Epub 2016 Feb 13.

Abstract

PURPOSE

To investigate the inter-image, inter-occasion and inter-examiner repeatability of NEC infrared thermo-tracer TH 9260 in assessing healthy and dry eyes.

METHODS

Ocular surface temperature (OST) was recorded using NEC infrared thermo-tracer TH 9260 on 21 healthy and 15 dry eyes. Data from the right eyes were analyzed. Marking of the ocular surface and OST acquisition was performed using a new 'diamond' demarcation method. Twelve OST indices were obtained at three different time points following a blink: 0s, 5s and 10s. Inter-image, inter-occasion and inter-examiner repeatability of the infrared ocular thermography was evaluated by calculating coefficients of repeatability (COR).

RESULTS

Ten out of the twelve tested OST indices had good repeatability with small inter-image variability (%COR: 0.2-0.9), inter-occasion variability (%COR: 2.1-3.7) and inter-examiner variability (%COR: 1.5-3.7) for the three studied time points. Two of the OST indices (temperature standard deviation of the region of interest and radial temperature difference) had poor repeatability with much larger inter-image variability (%COR: 8.9-140.7), inter-occasion variability (%COR: 47.5-153.5) and inter-examiner variability (%COR: 54.7-142.0) for the three studied time points.

CONCLUSIONS

Most of the metrics adopted in this assessment can be considered to be highly repeatable.

摘要

目的

研究NEC红外热成像仪TH 9260在评估健康眼和干眼时图像间、不同时间及不同检查者之间的可重复性。

方法

使用NEC红外热成像仪TH 9260记录21只健康眼和15只干眼的眼表温度(OST)。分析右眼数据。采用一种新的“菱形”划分方法进行眼表标记和OST采集。在眨眼后的三个不同时间点(0秒、5秒和10秒)获取12个OST指标。通过计算重复性系数(COR)评估红外眼热成像的图像间、不同时间及不同检查者之间的可重复性。

结果

在三个研究时间点,所测试的12个OST指标中有10个具有良好的可重复性,图像间变异性小(%COR:0.2 - 0.9),不同时间变异性小(%COR:2.1 - 3.7),不同检查者变异性小(%COR:1.5 - 3.7)。两个OST指标(感兴趣区域的温度标准差和径向温差)可重复性差,在三个研究时间点图像间变异性大得多(%COR:8.9 - 140.7),不同时间变异性大(%COR:47.5 - 153.5),不同检查者变异性大(%COR:54.7 - 142.0)。

结论

该评估中采用的大多数指标可被认为具有高度可重复性。