Suppr超能文献

比较多焦点人工晶状体植入术后的眼内散光。

Comparison of ocular straylight after implantation of multifocal intraocular lenses.

机构信息

From the Rotterdam Ophthalmic Institute (Łabuz, Reus), Rotterdam, the Department of Ophthalmology (Reus), Amphia Hospital, Breda, and the Netherlands Institute for Neuroscience (van den Berg), Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands; the Facultad de Óptica y Optometría (Łabuz), Universidad de Murcia, Murcia, Spain.

From the Rotterdam Ophthalmic Institute (Łabuz, Reus), Rotterdam, the Department of Ophthalmology (Reus), Amphia Hospital, Breda, and the Netherlands Institute for Neuroscience (van den Berg), Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands; the Facultad de Óptica y Optometría (Łabuz), Universidad de Murcia, Murcia, Spain.

出版信息

J Cataract Refract Surg. 2016 Apr;42(4):618-25. doi: 10.1016/j.jcrs.2016.02.022.

Abstract

UNLABELLED

A comprehensive review of the effect of multifocal intraocular lens (IOL) designs on postoperative ocular straylight was performed. Studies reporting straylight values obtained with the natural pupil using the C-Quant device after uneventful multifocal IOL implantation were included. The IOLs were categorized based on their material characteristics; that is, hydrophobicity and presence of colored chromophores. Age adjustment was achieved using the straylight age-dependency norm for pseudophakic eyes. This norm also served as a reference for comparing mean straylight levels of the various IOLs. The literature review identified 10 studies reporting 9 multifocal IOL designs. The hydrophilic IOLs showed less straylight than the hydrophobic IOLs by 0.08 log(s) (P = .001). Blue violet light-filtering IOLs showed less straylight than standard IOLs by 0.04 log(s), which was not statistically significant (P = .32). Hydrophobicity was a factor that significantly affected straylight in multifocal IOLs.

FINANCIAL DISCLOSURES

The Netherlands Academy of Arts and Sciences owns a patent on straylight measurement, with Dr. van den Berg as the inventor, and licenses it to Oculus Optikgeräte GmbH for the C-Quant instrument. No other author has a financial or proprietary interest in any material or method mentioned.

摘要

未加标签

对多焦点人工晶状体(IOL)设计对术后眼眩光的影响进行了全面回顾。纳入了报道在多焦点 IOL 植入后使用 C-Quant 设备通过自然瞳孔获得的眩光值的研究。根据其材料特性,将 IOL 分为疏水性和有色染料的存在;根据其材料特性将 IOL 分为疏水性和有色染料的存在。使用人工晶状体的眩光年龄依赖性标准对年龄进行了调整。该标准还用作比较各种 IOL 的平均眩光水平的参考。文献综述确定了 10 项研究,报道了 9 种多焦点 IOL 设计。亲水 IOL 的眩光比疏水 IOL 少 0.08 log(s)(P =.001)。蓝紫光滤光 IOL 的眩光比标准 IOL 少 0.04 log(s),但差异无统计学意义(P =.32)。疏水性是影响多焦点 IOL 眩光的一个因素。

财务披露

荷兰艺术与科学院拥有眩光测量专利,van den Berg 博士为发明人,并将其许可给 Oculus Optikgeräte GmbH 用于 C-Quant 仪器。没有其他作者在提到的任何材料或方法中拥有财务或所有权利益。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验