Suppr超能文献

用新型简易高效液相色谱法测定尿白蛋白

Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

作者信息

Klapkova Eva, Fortova Magdalena, Prusa Richard, Moravcova Libuse, Kotaska Karel

机构信息

Department of Medical Chemistry and Clinical Biochemistry, 2nd Faculty of Medicine and University Hospital Motol, Charles University, Prague, Czech Republic.

出版信息

J Clin Lab Anal. 2016 Nov;30(6):1226-1231. doi: 10.1002/jcla.22007. Epub 2016 May 31.

Abstract

BACKGROUND

A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive.

METHODS

Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA 400, Roche Diagnostics GmbH, Manheim, Germany.

RESULTS

The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test).

CONCLUSION

New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry.

摘要

背景

开发了一种简单的高效液相色谱(HPLC)方法,用于测定患者尿液样本中的白蛋白,且不存在共洗脱蛋白的情况,并与免疫比浊法测定白蛋白进行了比较。尿白蛋白是糖尿病患者重要的生物标志物,但其中一部分具有免疫非反应性。

方法

采用高效液相色谱(HPLC)、280nm紫外检测、Zorbax 300SB-C3柱测定白蛋白。使用商业试剂盒在德国曼海姆罗氏诊断有限公司的自动生化分析仪COBAS INTEGRA 400上进行免疫比浊分析。

结果

HLPC方法得到了充分验证。未发现与其他蛋白质(转铁蛋白、α-1-酸性糖蛋白、α-1-抗糜蛋白酶、抗胰蛋白酶、血红素结合蛋白)有明显干扰。将301份尿液样本的结果与免疫化学测定结果进行了比较。我们发现这些方法之间存在统计学显著差异(P = 0.0001,曼-惠特尼检验)。

结论

开发了一种新的简单HPLC方法,用于测定无共洗脱蛋白的尿白蛋白。我们的数据表明,HPLC方法具有高度特异性,且比免疫比浊法更灵敏。

相似文献

1
Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.
J Clin Lab Anal. 2016 Nov;30(6):1226-1231. doi: 10.1002/jcla.22007. Epub 2016 May 31.
3
Earlier detection of microalbuminuria in diabetic patients using a new urinary albumin assay.
Kidney Int. 2004 May;65(5):1850-5. doi: 10.1111/j.1523-1755.2004.00585.x.
4
Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.
Clin Chem. 2008 Sep;54(9):1504-10. doi: 10.1373/clinchem.2008.107508. Epub 2008 Jul 10.
5
High prevalence of immuno-unreactive intact albumin in urine of diabetic patients.
Am J Kidney Dis. 2003 Feb;41(2):336-42. doi: 10.1053/ajkd.2003.50041.
7
Evaluation of five immunoturbidimetric assays for urinary albumin quantification and their impact on albuminuria categorization.
Clin Biochem. 2014 Nov;47(16-17):250-3. doi: 10.1016/j.clinbiochem.2014.07.014. Epub 2014 Jul 26.
8
Analytical validation of an HPLC assay for urinary albumin.
Clin Chim Acta. 2006 May;367(1-2):150-5. doi: 10.1016/j.cca.2005.12.002. Epub 2006 Jan 19.
10
Quantitation of Albumin in Urine by Liquid Chromatography Tandem Mass Spectrometry.
Methods Mol Biol. 2016;1378:31-6. doi: 10.1007/978-1-4939-3182-8_4.

引用本文的文献

1
Recent Advances in Biosensor Technologies for Point-of-Care Urinalysis.
Biosensors (Basel). 2022 Nov 15;12(11):1020. doi: 10.3390/bios12111020.
3
Plasma circular RNA profiling of patients with gastric cancer and their droplet digital RT-PCR detection.
J Mol Med (Berl). 2018 Jan;96(1):85-96. doi: 10.1007/s00109-017-1600-y. Epub 2017 Nov 2.

本文引用的文献

1
The standardization of the urine albumin assays: no longer deferrable.
Clin Chem Lab Med. 2015 Oct;53(11):1657-9. doi: 10.1515/cclm-2015-0831.
4
Laboratory issues in measuring and reporting urine albumin.
Nephrol Dial Transplant. 2009 Mar;24(3):717-8. doi: 10.1093/ndt/gfp022.
5
Current issues in measurement and reporting of urinary albumin excretion.
Clin Chem. 2009 Jan;55(1):24-38. doi: 10.1373/clinchem.2008.106567. Epub 2008 Nov 21.
6
Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.
Clin Chem. 2008 Sep;54(9):1504-10. doi: 10.1373/clinchem.2008.107508. Epub 2008 Jul 10.
7
Analytical validation of an HPLC assay for urinary albumin.
Clin Chim Acta. 2006 May;367(1-2):150-5. doi: 10.1016/j.cca.2005.12.002. Epub 2006 Jan 19.
8
Coelution of other proteins with albumin during size-exclusion HPLC: Implications for analysis of urinary albumin.
Clin Chem. 2006 Mar;52(3):389-97. doi: 10.1373/clinchem.2005.057323. Epub 2006 Jan 5.
9
The analysis and characterisation of immuno-unreactive urinary albumin in healthy volunteers.
Clin Biochem. 2006 Feb;39(2):143-51. doi: 10.1016/j.clinbiochem.2005.10.013. Epub 2005 Dec 2.
10
Performance characteristics of an HPLC assay for urinary albumin.
Am J Clin Pathol. 2005 Aug;124(2):219-25. doi: 10.1309/F6WV-K152-5KLQ-GXR4.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验