Suppr超能文献

高眼压症的光学质量及相关因素:初步研究

Optical Quality and Related Factors in Ocular Hypertension: Preliminary Study.

作者信息

Wang Yu-Jing, Yang Yan-Ning, Huang Lin-Ying, Wang Bo, Han Yu-Can, Yan Jiang-Bo

机构信息

Department of ophthalmology, Renmin Hospital of Wuhan University, Wuhan, Hubei 430060, China.

出版信息

J Ophthalmol. 2016;2016:3071036. doi: 10.1155/2016/3071036. Epub 2016 May 12.

Abstract

Background. To evaluate the optical quality and related factors in patients with ocular hypertension (OHT). Methods. This was a prospective case-control study. A total of 12 eyes with OHT and 20 control eyes underwent testing with Optical Quality Analysis System II (OQAS II) to evaluate the modulation transfer function cut off frequency (MTF cutoff), the Strehl 2D ratio (SR), objective scatter index (OSI), tear-film mean OSI (TFOSI), and the OQAS values (OV100%,OV20%, and OV9%). Results. The optical quality of patients with OHT declined, with lower MTF cutoff (OHT 36.86 ± 7.11 cpd , controls 48.50 ± 4.04 cpd, t = -4.60, P < 0.05), lower SR (OHT 0.22 ± 0.04, controls 0.27 ± 0.05, t = -2.72, P < 0.05), lower OV100% (OHT 1.26 ± 0.25, controls 1.61 ± 0.14, t = -4.03, P < 0.05), lower OV20% (OHT 1.27 ± 0.27, controls 1.72 ± 0.20, t = -4.00, P < 0.05), and lower OV9% (OHT 1.30 ± 0.25, controls 1.69 ± 0.32, t = -2.28, P < 0.05). There were not any statistically significant differences in OSI and TFOSI. The MTF cutoff in patients with OHT was correlated significantly with age (r = -0.59, P < 0.05). Conclusions. Optical quality of patients with OHT is reduced, with lower MTF cutoff, SR, OV100%, OV20%, and OV9%. MTF cutoff is negatively related to age.

摘要

背景。评估高眼压症(OHT)患者的光学质量及相关因素。方法。这是一项前瞻性病例对照研究。共对12只高眼压症患眼和20只对照眼使用光学质量分析系统II(OQAS II)进行检测,以评估调制传递函数截止频率(MTF截止)、斯特列尔二维比率(SR)、客观散射指数(OSI)、泪膜平均OSI(TFOSI)以及OQAS值(OV100%、OV20%和OV9%)。结果。高眼压症患者的光学质量下降,MTF截止较低(高眼压症组36.86±7.11周/度,对照组48.50±4.04周/度,t=-4.60,P<0.05),SR较低(高眼压症组0.22±0.04,对照组0.27±0.05,t=-2.72,P<0.05),OV100%较低(高眼压症组1.26±0.25,对照组1.61±0.14,t=-4.03,P<0.05),OV20%较低(高眼压症组1.27±0.27,对照组1.72±0.20,t=-4.00,P<0.05),OV9%较低(高眼压症组1.30±0.25,对照组1.69±0.32,t=-2.28,P<0.05)。OSI和TFOSI无统计学显著差异。高眼压症患者的MTF截止与年龄显著相关(r=-0.59,P<0.05)。结论。高眼压症患者的光学质量降低,MTF截止、SR、OV100%、OV20%和OV9%较低。MTF截止与年龄呈负相关。

相似文献

1
Optical Quality and Related Factors in Ocular Hypertension: Preliminary Study.
J Ophthalmol. 2016;2016:3071036. doi: 10.1155/2016/3071036. Epub 2016 May 12.
3
Analysis of related factors of optical quality in healthy Chinese adults: a community-based population study.
Chin Med J (Engl). 2020 Oct 5;133(19):2308-2314. doi: 10.1097/CM9.0000000000000994.
4
[Objective assessment of comprehensive optical quality among adults at different ages].
Zhonghua Yan Ke Za Zhi. 2016 Jan;52(1):47-50. doi: 10.3760/cma.j.issn.0412-4081.2016.01.012.
6
Using Optical Quality Analysis System for predicting surgical parameters in age-related cataract patients.
PLoS One. 2020 Oct 12;15(10):e0240350. doi: 10.1371/journal.pone.0240350. eCollection 2020.
7
Early outcomes of vision and objective visual quality analysis after cataract surgery with trifocal intraocular lens implantation.
Int J Ophthalmol. 2019 Oct 18;12(10):1575-1581. doi: 10.18240/ijo.2019.10.09. eCollection 2019.
8
Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.
PLoS One. 2015 Nov 4;10(11):e0142189. doi: 10.1371/journal.pone.0142189. eCollection 2015.
9
The impact of dry eye disease on retinal image quality in children.
Cont Lens Anterior Eye. 2024 Jun;47(3):102168. doi: 10.1016/j.clae.2024.102168. Epub 2024 Apr 18.
10
Repeatability and reproducibility of a double-pass optical quality analysis device.
PLoS One. 2015 Feb 3;10(2):e0117587. doi: 10.1371/journal.pone.0117587. eCollection 2015.

引用本文的文献

2
Clinical application of accommodating intraocular lens.
Int J Ophthalmol. 2018 Jun 18;11(6):1028-1037. doi: 10.18240/ijo.2018.06.22. eCollection 2018.

本文引用的文献

1
Ocular hypertension: an approach to assessment and management.
Can J Ophthalmol. 2014 Dec;49(6):489-96. doi: 10.1016/j.jcjo.2014.06.013.
2
Grading nuclear, cortical and posterior subcapsular cataracts using an objective scatter index measured with a double-pass system.
Br J Ophthalmol. 2012 Sep;96(9):1204-10. doi: 10.1136/bjophthalmol-2011-301055. Epub 2012 Jul 11.
3
Systematic review of the agreement of tonometers with Goldmann applanation tonometry.
Ophthalmology. 2012 Aug;119(8):1552-7. doi: 10.1016/j.ophtha.2012.02.030. Epub 2012 May 10.
4
Intraocular pressure and central corneal thickness in premature and full-term newborns.
J AAPOS. 2011 Aug;15(4):367-9. doi: 10.1016/j.jaapos.2011.04.004. Epub 2011 Aug 4.
5
Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes.
J Cataract Refract Surg. 2011 Aug;37(8):1481-7. doi: 10.1016/j.jcrs.2011.03.036.
6
7
Optical quality and intraocular scattering in a healthy young population.
Clin Exp Optom. 2011 Mar;94(2):223-9. doi: 10.1111/j.1444-0938.2010.00535.x. Epub 2010 Nov 17.
8
Effect of laser in situ keratomileusis on vision analyzed using preoperative optical quality.
J Cataract Refract Surg. 2010 Nov;36(11):1945-53. doi: 10.1016/j.jcrs.2010.05.029.
10
Use of the double-pass technique to quantify ocular scatter in patients with uveitis: a pilot study.
Ophthalmologica. 2011;225(1):61-6. doi: 10.1159/000316690. Epub 2010 Aug 14.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验