Department of Plant and Environmental Sciences, University of Copenhagen, Thorvaldsensvej 40, 1871 Frederiksberg, Denmark.
Faculty of Civil and Environmental Engineering, Ostfalia University of Applied Sciences, Suderburg, 29556, Germany.
Bioresour Technol. 2016 Oct;218:1249-52. doi: 10.1016/j.biortech.2016.06.099. Epub 2016 Jun 27.
The influence of the reactor wall attached biofilm on the nutrient removal performance was investigated in an open photobioreactor during long-term operation. Total nitrogen and phosphorus removal efficiencies were statistically similar between reactor with (reactor A) and without (reactor B) biofilm at the Hydraulic Retention Time (HRT) of 18, 13.5 and 9days. When the HRT reduced to 8days, total nitrogen and phosphorus removal efficiencies in the reactor A were 42.95±5.11% and 97.97±1.12%, respectively, while significant lower removal efficiencies (38.06±5.80% for total nitrogen and 83.14±8.16% for phosphorus) were obtained in the reactor B. The VSS concentrations throughout the test were statistically similar for the two reactors, with a mean value of 0.63±0.25g/l for reactor A and 0.69±0.20g/l for reactor B. This study indicated that the reactor wall attached biofilm supported high phosphorus and nitrogen removal, which may provide insight into the practical implementation of microalgae-based wastewater treatment.
在长期运行过程中,在开放光生物反应器中研究了附着在反应器壁上的生物膜对养分去除性能的影响。在水力停留时间(HRT)为 18、13.5 和 9 天时,具有(反应器 A)和不具有(反应器 B)生物膜的反应器的总氮和总磷去除效率在统计学上相似。当 HRT 降低至 8 天时,反应器 A 中的总氮和总磷去除效率分别为 42.95±5.11%和 97.97±1.12%,而在反应器 B 中则获得了明显较低的去除效率(总氮为 38.06±5.80%,总磷为 83.14±8.16%)。整个测试过程中,两个反应器的 VSS 浓度在统计学上相似,反应器 A 的平均值为 0.63±0.25g/l,反应器 B 的平均值为 0.69±0.20g/l。本研究表明,附着在反应器壁上的生物膜支持高磷和氮的去除,这可能为基于微藻的废水处理的实际实施提供了一些见解。