This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (µTBS) of a 3-step total etch and a 2-step self-etch adhesive system.
The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For µTBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and µTBS were assessed by one-way and three-way ANOVA, respectively, and Tukey's test (α=5%).
RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in µTBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the µTBS means occurred in both storage times.
RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface.
本研究调查了荧光染料罗丹明B(RB)对牙科复合修复体界面微观形态分析的影响,该修复体使用了三步全酸蚀和两步自酸蚀粘结系统,研究其对吸水性/溶解性(WS/WSL)以及与牙本质的微拉伸粘结强度(µTBS)的影响。
将Adper Scotchbond多功能粘结剂(MP)和Clearfil SE粘结剂(SE)与0.1 mg/mL的RB混合。对于WS/WSL测试,制备固化树脂圆盘(直径5.0 mm×厚0.8 mm),并分为四组(n = 10):MP、MP-RB、SE和SE-RB。对于µTBS评估,将拔除的人类第三磨牙(n = 40)制备平坦的咬合面牙本质,并分为相同的实验组(n = 10)。在粘结和修复程序完成后,将标本切成矩形梁,保存在水中,并在7天或12个月后进行测试。在光学显微镜(×40)下对断裂标本的失效模式进行定性评估。WS/WSL和µTBS的数据分别通过单因素和三因素方差分析进行评估,并采用Tukey检验(α = 5%)。
RB增加了MP和SE的WSL。另一方面,MP和SE的WS均不受RB添加的影响。在7天或1年时,未观察到MP和MP-RB之间µTBS有显著差异,而对于SE,在两个储存时间内µTBS平均值均下降。
RB应谨慎应用于非简化的粘结系统,因为它可能会干扰其物理力学性能,导致对粘结界面的误判。