We tested the feasibility of using porcine small intestinal submucosal extracellular matrix (CorMatrix) for aortic valve (AV) repair in porcine model examining its resorption and remodeling potential. The non-coronary cusp was replaced with CorMatrix in four animals for 120 days. Valve function was assessed by echocardiography. Explants were examined by histology, immunohistochemistry, and collagen assessment. CorMatrix was almost totally replaced with tissue resembling the native cusp with a partial two-layer architecture. However, function was lost due to thickening and calcification. Tested in high-pressure AV position in a pig model, CorMatrix degrades and remodels, but also loses function.