Suppr超能文献

数字根尖片与传统根尖片在检测种植体-基台界面不匹配方面的准确性。

Accuracy of Digital Versus Conventional Periapical Radiographs to Detect Misfit at the Implant-Abutment Interface.

作者信息

Cançado Oliveira Bruno Fernando, Valerio Claudia Scigliano, Jansen Wellington Corrêa, Zenóbio Elton Gonçalves, Manzi Flávio Ricardo

出版信息

Int J Oral Maxillofac Implants. 2016 Sep-Oct;31(5):1023-9. doi: 10.11607/jomi.4525.

Abstract

PURPOSE

Misfit is a risk factor for rehabilitation with implants, and its detection is of fundamental importance to the success of treatment with implants. The use of appropriate radiographic imaging is key for a good prognosis. The aim of this study was to compare the efficacy of film and digital radiographs for the detection of misfit at the implant-abutment interface.

MATERIALS AND METHODS

Digital and conventional (manual and automatic processing) radiography was performed in seven test specimens, each one with a different vertical misfit between the abutment and the platform of the implant. Scanning electron microscopy was used to confirm the misfit and to measure it. Five dental radiologists independently and blindly evaluated the images. Cohen's kappa with linear weighting was calculated to determine interexaminer and intraexaminer concordance. Statistical analyses were performed using the Cochran's Q test and the receiver operating characteristic curve (ROC).

RESULTS

Interexaminer analysis showed that the kappa value was equal to 0.74, whereas the average kappa value in the intraexaminer evaluation was 0.90. Digital imaging showed the largest area on the ROC graph, and conventional images with manual processing showed the smallest area. The images obtained through conventional radiography with both manual and automatic processing showed statistically significant differences from the measurement of the gold standard (P < .05).

CONCLUSION

Digital imaging can be used to evaluate misfit at the implant-abutment interface. Conventional systems of radiographic imaging do not provide sufficient information to evaluate misfit at the implant-abutment interface.

摘要

目的

适配不良是种植体修复的一个风险因素,其检测对于种植体治疗的成功至关重要。使用合适的放射成像对于良好的预后至关重要。本研究的目的是比较胶片和数字X线片在检测种植体-基台界面适配不良方面的效果。

材料与方法

对七个测试样本进行了数字和传统(手动和自动处理)放射摄影,每个样本在基台与种植体平台之间具有不同的垂直适配不良。使用扫描电子显微镜确认并测量适配不良情况。五名牙科放射科医生独立且盲法评估图像。计算带有线性加权的科恩kappa系数以确定检查者间和检查者内的一致性。使用 Cochr an's Q检验和受试者工作特征曲线(ROC)进行统计分析。

结果

检查者间分析显示kappa值等于0.74,而检查者内评估的平均kappa值为0.90。数字成像在ROC图上显示的面积最大,手动处理的传统图像显示的面积最小。通过手动和自动处理的传统放射摄影获得的图像与金标准测量结果存在统计学显著差异(P <.05)。

结论

数字成像可用于评估种植体-基台界面的适配不良。传统的放射成像系统无法提供足够的信息来评估种植体-基台界面的适配不良。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验