Suppr超能文献

用于胸壁放射治疗期间同时进行剂量累积和监测的半透明聚(乙烯醇)水凝胶剂量计。

Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy.

机构信息

Yarmouk University.

出版信息

J Appl Clin Med Phys. 2016 Sep 8;17(5):308-319. doi: 10.1120/jacmp.v17i5.6148.

Abstract

Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phantom was shifted by ± 2, ± 3, and ± 5 mm from the planned position in the anterior/posterior (A/P) direction; these shifts represent setup errors and the uncertainty associated with lung filling during breath-hold. The two-dimensional absolute dose distributions measured in the cryogel at the planned position were compared with the distributions at all shifts from this position using gamma analysis (3%/3 mm, 10% threshold). For shifts of ± 2, ± 3, and ± 5 mm the passing rates ranged from 94.3% to 95.6%, 74.0% to 78.8%, and 17.5% to 22.5%, respectively. These results are consistent with the same gamma analysis performed on dose planes calculated in the middle of the cryogel and on the phantom surface using our treatment plan-ning system, which ranged from 94.3% to 95.0%, 76.8% to 77.9%, and 23.5% to 24.3%, respectively. The Pinnacle dose planes were then scaled empirically and compared to the cryogel measurements. Using the same gamma metric, the pass rates ranged from 97.0% to 98.4%. The results of this study suggest that cryogels may be used as both a buildup material and to evaluate errors in chest wall treat-ment positioning during deep-inspiration breath-hold delivery. The cryogels are sensitive to A/P chest wall shifts of less than 3 mm, which potentially allows for the detection of clinically relevant errors.

摘要

采用 5 毫米厚的放射化学聚(聚乙烯醇)冷冻胶来监测胸壁放射治疗的实施情况,这种冷冻胶同时也提供了附加材料。这些冷冻胶被用于检测定位误差,并测量深吸气屏气治疗胸壁过程中移位的影响。将 RANDO 体模在前后(AP)方向上偏离计划位置±2、±3 和±5 毫米进行移位;这些移位代表了设置误差和肺充气在屏气期间的不确定性。在计划位置上用二维绝对剂量分布在冷冻胶中进行测量,并与从该位置的所有移位位置使用伽马分析(3%/3 毫米,10%阈值)进行比较。对于±2、±3 和±5 毫米的移位,通过率分别为 94.3%至 95.6%、74.0%至 78.8%和 17.5%至 22.5%。这些结果与在冷冻胶中间和体模表面使用我们的治疗计划系统计算的剂量平面上进行的相同伽马分析一致,其通过率分别为 94.3%至 95.0%、76.8%至 77.9%和 23.5%至 24.3%。然后,根据经验对 Pinnacle 剂量平面进行缩放,并与冷冻胶测量值进行比较。使用相同的伽马度量,通过率范围为 97.0%至 98.4%。这项研究的结果表明,冷冻胶可以用作附加材料,并评估深吸气屏气治疗中胸壁定位的误差。冷冻胶对小于 3 毫米的 AP 胸壁移位很敏感,这可能允许检测到临床相关的误差。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4f85/5874105/e26e3ee2a7b8/ACM2-17-308-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验