Suppr超能文献

使用人工关节超声检查评估一种用于诊断骨与关节感染的商用多重聚合酶链反应(Unyvero i60)。

Evaluation of a commercial multiplex PCR (Unyvero i60) designed for the diagnosis of bone and joint infections using prosthetic-joint sonication.

作者信息

Prieto-Borja Laura, Rodriguez-Sevilla Graciela, Auñon Alvaro, Pérez-Jorge Concepción, Sandoval Enrique, Garcia-Cañete Joaquín, Gadea Ignacio, Fernandez-Roblas Ricardo, Blanco Antonio, Esteban Jaime

机构信息

Department of Clinical Microbiology, IIS-Fundación Jiménez Díaz, UAM, Av. Reyes Católicos 2, 28040 Madrid, Spain.

Department of Orthopaedic Surgery, IIS-Fundación Jiménez Díaz, UAM, Av. Reyes Católicos 2, 28040 Madrid, Spain.

出版信息

Enferm Infecc Microbiol Clin. 2017 Apr;35(4):236-242. doi: 10.1016/j.eimc.2016.09.007. Epub 2016 Oct 18.

Abstract

BACKGROUND

The development of sonication protocols over the last few years has improved the sensitivity of conventional cultures for the diagnosis of prosthetic-joint infection (PJI). However, the development of a new, specifically designed kit for the molecular diagnosis of PJI could provide a major improvement in this field.

METHODS

Prostheses retrieved from patients who underwent implant removal from May 2014 to May 2015 were sent for culture, and processed according to a previously defined protocol that included sonication. Furthermore, 180 microlitres of sonication fluid were used to carry out the multiplex PCR test (Unyvero i60 system). A comparison of the sensitivity, specificity, positive (PPV) and negative (NPV) predictive value, was performed. The study was approved by the Clinical Research Ethics Committee.

RESULTS

The analysis included 88 prostheses from 68 patients (1.29 prostheses/patient). The type of prostheses studied were knee (n=55), total hip (n=26), partial hip (n=5), and shoulder (n=2). Twenty-nine patients were diagnosed with a PJI (15 delayed, 12 acute, and 2 haematogenous infections). In 24 cases, the result of the PCR was positive, all but 1 corresponding to patients with clinical criteria of PJI. Nine resistance mechanisms were detected from 5 samples. The Unyvero i60 system showed slightly better results than traditional culture in terms of specificity and PPV.

CONCLUSIONS

The Unyvero i60 system may play a role in rapid diagnosis of PJI, due to its high specificity and PPV. However, despite these results, cultures have to be performed to detect organisms not detected by the system.

摘要

背景

在过去几年中,超声处理方案的发展提高了传统培养方法对人工关节感染(PJI)诊断的敏感性。然而,开发一种专门设计用于PJI分子诊断的新型试剂盒可能会在该领域带来重大改进。

方法

将2014年5月至2015年5月接受植入物取出手术患者的假体送去培养,并按照先前定义的包括超声处理的方案进行处理。此外,使用180微升超声处理液进行多重PCR检测(Unyvero i60系统)。进行了敏感性、特异性、阳性(PPV)和阴性(NPV)预测值的比较。该研究获得了临床研究伦理委员会的批准。

结果

分析包括来自68名患者的88个假体(每位患者1.29个假体)。研究的假体类型为膝关节(n = 55)、全髋关节(n = 26)、部分髋关节(n = 5)和肩关节(n = 2)。29名患者被诊断为PJI(15例为延迟性感染,12例为急性感染,2例为血源性感染)。在24例中,PCR结果为阳性,除1例之外,所有结果均对应具有PJI临床标准的患者。从5个样本中检测到9种耐药机制。Unyvero i60系统在特异性和PPV方面比传统培养显示出稍好的结果。

结论

由于其高特异性和PPV,Unyvero i60系统可能在PJI的快速诊断中发挥作用。然而,尽管有这些结果,仍必须进行培养以检测该系统未检测到的微生物。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验