Suppr超能文献

年轻无症状参与者足部特定肌肉的非负重和负重超声检查:一项描述性和可靠性研究

Non-Weight-Bearing and Weight-Bearing Ultrasonography of Select Foot Muscles in Young, Asymptomatic Participants: A Descriptive and Reliability Study.

作者信息

Battaglia Patrick J, Mattox Ross, Winchester Brett, Kettner Norman W

机构信息

Radiology Department, Logan University, Chesterfield, MO.

Radiology Department, Logan University, Chesterfield, MO.

出版信息

J Manipulative Physiol Ther. 2016 Nov-Dec;39(9):655-661. doi: 10.1016/j.jmpt.2016.10.001.

Abstract

OBJECTIVE

The primary aim of this study was to determine the reliability of diagnostic ultrasound imaging for select intrinsic foot muscles using both non-weight-bearing and weight-bearing postures. Our secondary aim was to describe the change in muscle cross-sectional area (CSA) and dorsoplantar thickness when bearing weight.

METHODS

An ultrasound examination was performed with a linear ultrasound transducer operating between 9 and 12 MHz. Long-axis and short-axis ultrasound images of the abductor hallucis, flexor digitorum brevis, and quadratus plantae were obtained in both the non-weight-bearing and weight-bearing postures. Two examiners independently collected ultrasound images to allow for interexaminer and intraexaminer reliability calculation. The change in muscle CSA and dorsoplantar thickness when bearing weight was also studied.

RESULTS

There were 26 participants (17 female) with a mean age of 25.5 ± 3.8 years and a mean body mass index of 28.0 ± 7.8 kg/m. Inter-examiner reliability was excellent when measuring the muscles in short axis (intraclass correlation coefficient >0.75) and fair to good in long axis (intraclass correlation coefficient >0.4). Intraexaminer reliability was excellent for the abductor hallucis and flexor digitorum brevis and ranged from fair to good to excellent for the quadratus plantae. Bearing weight did not reduce interexaminer or intraexaminer reliability. All muscles exhibited a significant increase in CSA when bearing weight.

CONCLUSIONS

This is the first report to describe weight-bearing diagnostic ultrasound of the intrinsic foot muscles. Ultrasound imaging is reliable when imaging these muscles bearing weight. Furthermore, muscle CSA increases in the weight-bearing posture.

摘要

目的

本研究的主要目的是确定使用非负重和负重姿势对足部特定内在肌肉进行诊断性超声成像的可靠性。我们的次要目的是描述负重时肌肉横截面积(CSA)和背跖厚度的变化。

方法

使用频率在9至12MHz之间的线性超声换能器进行超声检查。在非负重和负重姿势下均获取拇展肌、趾短屈肌和跖方肌的长轴和短轴超声图像。两名检查者独立收集超声图像,以进行检查者间和检查者内可靠性计算。还研究了负重时肌肉CSA和背跖厚度的变化。

结果

共有26名参与者(17名女性),平均年龄为25.5±3.8岁,平均体重指数为28.0±7.8kg/m²。测量短轴肌肉时检查者间可靠性极佳(组内相关系数>0.75),长轴测量时为中等至良好(组内相关系数>0.4)。检查者内可靠性方面,拇展肌和趾短屈肌极佳,跖方肌为中等至良好至极佳。负重并未降低检查者间或检查者内可靠性。所有肌肉在负重时CSA均显著增加。

结论

这是首篇描述足部内在肌肉负重诊断性超声的报告。对这些负重肌肉进行超声成像时具有可靠性。此外,负重姿势下肌肉CSA增加。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验