Suppr超能文献

基于功能化双壁碳纳米管修饰的双丝网印刷电极电化学免疫传感器同时测定血清和唾液中的白细胞介素-1β和肿瘤坏死因子-α

Electrochemical immunosensor for simultaneous determination of interleukin-1 beta and tumor necrosis factor alpha in serum and saliva using dual screen printed electrodes modified with functionalized double-walled carbon nanotubes.

机构信息

Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, Ciudad Universitaria s/n, 28040, Madrid, Spain.

Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, Ciudad Universitaria s/n, 28040, Madrid, Spain.

出版信息

Anal Chim Acta. 2017 Mar 22;959:66-73. doi: 10.1016/j.aca.2016.12.034. Epub 2017 Jan 2.

Abstract

Dual screen-printed carbon electrodes modified with 4-carboxyphenyl-functionalized double-walled carbon nanotubes (HOOC-Phe-DWCNTs/SPCEs) have been used as scaffolds for the preparation of electrochemical immunosensors for the simultaneous determination of the cytokines Interleukin-1β (IL-1β) and factor necrosis tumor α (TNF-α). IL-1β. Capture antibodies were immobilized onto HOOC-Phe-DWCNTs/SPCEs in an oriented form making using the commercial polymeric coating Mix&Go™. Sandwich type immunoassays with amperometric signal amplification through the use of poly-HRP-streptavidin conjugates and HO as HRP substrate and hydroquinone as redox mediator were implemented. Upon optimization of the experimental variables affecting the immunosensor performance, the dual immunosensor allows ranges of linearity extending between 0.5 and 100 pg/mL and from 1 to 200 pg/mL for IL-1β and TNF-α, respectively, these ranges being adequate for the determination of the cytokines in clinical samples. The achieved limits of detection were 0.38 pg/mL (IL-1β) and 0.85 pg/mL (TNF-α). In addition, the dual immunosensor exhibits excellent reproducibility of the measurements, storage stability of the anti-IL-Phe-DWCNTs/SPCE and anti-TNF-Phe-DWCNTs/SPCE conjugates, and selectivity as well as negligible cross-talking. The dual immunosensor was applied to the simultaneous determination of IL-1β and TNF-α in human serum spiked at clinically relevant concentration levels and in real saliva samples.

摘要

双丝网印刷碳电极用 4-羧基苯功能化的双壁碳纳米管(HOOC-Phe-DWCNTs/SPCEs)修饰,用作同时测定细胞因子白细胞介素-1β(IL-1β)和肿瘤坏死因子-α(TNF-α)的电化学免疫传感器的支架。IL-1β。捕获抗体以定向形式固定在 HOOC-Phe-DWCNTs/SPCEs 上,使用商业聚合涂层 Mix&Go™进行固定。通过使用多-HRP-链霉亲和素缀合物和 HO 作为 HRP 底物以及对苯二酚作为氧化还原介体进行安培信号放大,实现了夹心型免疫测定。在优化影响免疫传感器性能的实验变量后,双免疫传感器允许 IL-1β和 TNF-α的线性范围分别在 0.5 和 100 pg/mL 之间以及 1 和 200 pg/mL 之间扩展,这些范围适用于临床样品中细胞因子的测定。实现的检测限分别为 0.38 pg/mL(IL-1β)和 0.85 pg/mL(TNF-α)。此外,双免疫传感器表现出测量的出色重现性、抗 IL-Phe-DWCNTs/SPCE 和抗 TNF-Phe-DWCNTs/SPCE 缀合物的存储稳定性以及选择性和可忽略的串扰。该双免疫传感器应用于同时测定人血清中临床相关浓度水平和实际唾液样品中的 IL-1β和 TNF-α。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验