Abstract

BACKGROUND

The elevated vacuum suspension system has demonstrated unique health benefits for amputees, but the effect of vacuum pressure values on gait characteristics is still unclear. The purpose of this study was to investigate the effects of elevated vacuum levels on temporal parameters, kinematics and kinetics for unilateral transtibial amputees.

METHODS

Three-dimensional gait analysis was conducted in 9 unilateral transtibial amputees walking at a controlled speed with five vacuum levels ranging from 0 to 20inHg, and also in 9 able-bodied subjects walking at self-preferred speed. Repeated ANOVA and Dunnett's t-test were performed to determine the effect of vacuum level and limb for within subject and between groups.

FINDINGS

The effect of vacuum level significantly affected peak hip external rotation and external knee adduction moment. Maximum braking and propulsive ground reaction forces generally increased for the residual limb and decreased for the intact limb with increasing vacuum. Additionally, the intact limb experienced an increased loading due to gait asymmetry for several variables.

INTERPRETATION

There was no systematic vacuum level effect on gait. Higher vacuum levels, such as 15 and 20inHg, were more comfortable and provided some relief to the intact limb, but may also increase the risk of osteoarthritis of the residual limb due to the increased peak external hip and knee adduction moments. Very low vacuum should be avoided because of the negative effects on gait symmetry. A moderate vacuum level at 15inHg is suggested for unilateral transtibial amputees with elevated vacuum suspension.

摘要

背景

高位真空悬吊系统已被证明对截肢者具有独特的健康益处,但真空压力值对步态特征的影响仍不清楚。本研究的目的是调查高位真空水平对单侧胫截肢者的时间参数、运动学和动力学的影响。

方法

对9名单侧胫截肢者以0至20英寸汞柱的五个真空水平以受控速度行走进行三维步态分析,同时对9名健全受试者以自我偏好的速度行走进行三维步态分析。进行重复方差分析和邓尼特t检验以确定真空水平和肢体对受试者内和组间的影响。

结果

真空水平的影响显著影响了髋关节最大外旋和膝关节最大内收力矩。随着真空度增加,残肢的最大制动和推进地面反作用力通常增加,健全肢体的则减小。此外,由于步态不对称,健全肢体在几个变量上承受的负荷增加。

解读

真空水平对步态没有系统性影响。较高的真空水平,如15和20英寸汞柱,更舒适,能为健全肢体提供一些缓解,但由于髋关节和膝关节最大外展力矩增加,也可能增加残肢患骨关节炎的风险。应避免极低的真空度,因为其对步态对称性有负面影响。对于使用高位真空悬吊的单侧胫截肢者,建议使用15英寸汞柱的中等真空度。

相似文献

1
Vacuum level effects on gait characteristics for unilateral transtibial amputees with elevated vacuum suspension.
Clin Biomech (Bristol). 2017 Mar;43:95-101. doi: 10.1016/j.clinbiomech.2017.02.008. Epub 2017 Feb 14.
2
Vacuum level effects on knee contact force for unilateral transtibial amputees with elevated vacuum suspension.
J Biomech. 2017 May 24;57:110-116. doi: 10.1016/j.jbiomech.2017.04.013. Epub 2017 Apr 20.
3
Biomechanical risk factors for knee osteoarthritis when using passive and powered ankle-foot prostheses.
Clin Biomech (Bristol). 2014 Dec;29(10):1186-92. doi: 10.1016/j.clinbiomech.2014.09.005. Epub 2014 Sep 18.
4
A comparison of vacuum and KBM prosthetic fitting for unilateral transtibial amputees using the Gait Profile Score.
Gait Posture. 2015 Feb;41(2):683-7. doi: 10.1016/j.gaitpost.2015.01.026. Epub 2015 Feb 4.
5
Transtibial amputee gait during slope walking with the unity suspension system.
Gait Posture. 2018 Sep;65:205-212. doi: 10.1016/j.gaitpost.2018.07.059. Epub 2018 Jul 26.
6
Transtibial amputee gait with the unity suspension system.
Disabil Rehabil Assist Technol. 2020 Apr;15(3):350-356. doi: 10.1080/17483107.2019.1579000. Epub 2019 Feb 27.
7
The effects of prosthetic foot stiffness on transtibial amputee walking mechanics and balance control during turning.
Clin Biomech (Bristol). 2017 Nov;49:56-63. doi: 10.1016/j.clinbiomech.2017.08.003. Epub 2017 Aug 15.
9
Gait initiation in lower limb amputees.
Gait Posture. 2008 Apr;27(3):423-30. doi: 10.1016/j.gaitpost.2007.05.013. Epub 2007 Jul 12.

引用本文的文献

1
Effects of Unity Prosthetic Elevated Vacuum Suspension System on Minimum Swing Toe Clearance.
Can Prosthet Orthot J. 2021 Oct 23;5(1):36847. doi: 10.33137/cpoj.v5i1.36847. eCollection 2022.
4
Modeling the mechanics of elevated vacuum systems in prosthetic sockets.
Med Eng Phys. 2020 Oct;84:75-83. doi: 10.1016/j.medengphy.2020.07.019. Epub 2020 Jul 28.
5
Real time monitoring of transtibial elevated vacuum prostheses: A case series on socket air pressure.
PLoS One. 2018 Oct 22;13(10):e0202716. doi: 10.1371/journal.pone.0202716. eCollection 2018.
6
Effects of the unity vacuum suspension system on transtibial gait for simulated non-level surfaces.
PLoS One. 2018 Jun 14;13(6):e0199181. doi: 10.1371/journal.pone.0199181. eCollection 2018.

本文引用的文献

2
Biomechanics and physiological parameters during gait in lower-limb amputees: a systematic review.
Gait Posture. 2011 Apr;33(4):511-26. doi: 10.1016/j.gaitpost.2011.02.003. Epub 2011 Mar 10.
5
6
The prevalence of osteoarthritis of the intact hip and knee among traumatic leg amputees.
Arch Phys Med Rehabil. 2009 Mar;90(3):440-6. doi: 10.1016/j.apmr.2008.08.220.
8
Sex modifies the relationship between age and gait: a population-based study of older adults.
J Gerontol A Biol Sci Med Sci. 2008 Feb;63(2):165-70. doi: 10.1093/gerona/63.2.165.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验