Suppr超能文献

[Preliminary analysis of lung function of population with biofuel smoke exposure].

作者信息

Zhao D X, Chen S Y, Zhou Y M, Li X C, Liu S, Chen L, Pu J D, Ran P X

机构信息

State Key Laboratory of Respiratory Disease, Guangzhou Institute of Respiratory Diseases, First Affiliated Hospital, Guangzhou Medical University of Guangzhou, Guangzhou 510120, China.

出版信息

Zhonghua Jie He He Hu Xi Za Zhi. 2017 May 12;40(5):349-353. doi: 10.3760/cma.j.issn.1001-0939.2017.05.008.

Abstract

To analyse the impaired lung functions of people with biofuel smoke exposure. Nonsmokers with biofuel smoke exposure were selected as research objects in a mountainous area of northern Guangdong where the families used biofuels as main energies and the nonsmokers without biofuel smoke exposure in the same area as control. Questionnaire interviews and spirometry tests were performed on all subjects. To analyse the differences of lung functions in both. Seventy hundred and seventeen subjects were enro1led in this study.There were 530 nonsmokers with biofuel smoke exposure(observation group) including 442 women and 88 men, average age 54±10. There were 187 nonsmokers without biofuel smoke exposure(control group) including 141 women and 46 men, average age 54±10. There was no significant difference between two groups in age, height, weight, BMI, waist circumference, hip circumference and waist/hip ratio(>0.05). The pulmonary ventilation function index(FEV(1)%Pred, FEV(1)/FVC) in the observation group was significantly less than that in control group [(100±18) .(106±25); (80±10) .(83±6) respectively, <0.05]. Small airway function index(PEF25, PEF50, PEF75, MMPEF and MMPEF%Pred) was significantly less than that in control group(<0.01). According to the univariate regression analysis and multivariate regression analysis, regression coefficients between BIOFUEL-INDEX and FEV/FVC was -0.1, 95%(-0.1, -0.1, <0.01). According to the threshold analysis, the vertice of BIOFUEL-INDEX was 46.0, where the predicted Y value was 81.76, 95% (80.2, 83.33). When BIOFUEL-INDEX<46.0, the regression coefficient was 0, 95% (-0.1, 0.0)(>0.05); when BIOFUEL-INDEX> 46.0, the regression coefficient 2 was -0.1, 95% (-0.2, -0.1)(<0.01). The difference between coefficient 2 and 1 was -0.1, 95% (-0.2, 0.0), which was statistically significant (<0.05). The Log-Likelihood ratio between Model I and Model Ⅱ had statistical significance (=0.019). The biofuel smokes exposure causes damages in lung function.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验