Abstract

BACKGROUND

There is a significant rate of sensitization worldwide to the oxidized fragrance terpenes limonene and linalool. Patch testing to oxidized terpenes is not routinely carried out; the ideal patch test concentration is unknown.

OBJECTIVES

To determine the best test concentrations for limonene and linalool hydroperoxides, added to the British baseline patch test series, to optimize detection of true allergy and to minimize irritant reactions.

METHODS

During 2013-2014, 4563 consecutive patients in 12 U.K. centres were tested to hydroperoxides of limonene in petrolatum (pet.) 0·3%, 0·2% and 0·1%, and hydroperoxides of linalool 1·0%, 0·5% and 0·25% pet. Irritant reactions were recorded separately from doubtful reactions. Concomitant reactions to other fragrance markers and clinical relevance were documented.

RESULTS

Limonene hydroperoxide 0·3% gave positive reactions in 241 (5·3%) patients, irritant reactions in 93 (2·0%) and doubtful reactions in 110 (2·4%). Linalool hydroperoxide 1·0% gave positive reactions in 352 (7·7%), irritant reactions in 178 (3·9%) and doubtful reactions in 132 (2·9%). A total of 119 patients with crescendo reactions to 0·3% limonene would have been missed if only tested with 0·1% and 131 patients with crescendo reactions to 1·0% linalool would have been missed if only tested with 0·25%. In almost two-thirds of patients with positive patch tests to limonene and linalool the reaction was clinically relevant. The majority of patients did not react to any fragrance marker in the baseline series.

CONCLUSIONS

We recommend that limonene hydroperoxides be tested at 0·3% and linalool hydroperoxides at 1·0% in the British baseline patch test series.

摘要

背景

全世界范围内存在对氧化型香料萜烯柠檬烯和芳樟醇致敏的高发生率。目前尚未常规进行氧化型萜烯斑贴试验,也尚未明确理想的斑贴试验浓度。

目的

确定添加至英国基本斑贴试验系列的柠檬烯和芳樟醇氢过氧化物的最佳试验浓度,以优化对真正过敏的检测,并将刺激性反应降至最低。

方法

在 2013-2014 年期间,英国 12 个中心的 4563 例连续患者接受了柠檬烯氢过氧化物在矿脂中的测试(浓度分别为 0·3%、0·2%和 0·1%)和芳樟醇氢过氧化物在矿脂中的测试(浓度分别为 1·0%、0·5%和 0·25%)。单独记录刺激性反应和可疑反应。同时记录了对其他香料标志物的反应和临床相关性。

结果

柠檬烯氢过氧化物 0·3%引起 241 例(5·3%)患者阳性反应,93 例(2·0%)出现刺激性反应,110 例(2·4%)出现可疑反应。芳樟醇氢过氧化物 1·0%引起 352 例(7·7%)患者阳性反应,178 例(3·9%)出现刺激性反应,132 例(2·9%)出现可疑反应。如果仅用 0·1%测试,119 例对 0·3%柠檬烯产生递增反应的患者将被漏诊,如果仅用 0·25%测试,131 例对 1·0%芳樟醇产生递增反应的患者将被漏诊。在对柠檬烯和芳樟醇进行阳性斑贴试验的患者中,近三分之二的患者的反应具有临床相关性。大多数患者对基本斑贴试验系列中的任何香料标志物均无反应。

结论

我们建议在英国基本斑贴试验系列中,柠檬烯氢过氧化物的测试浓度为 0·3%,芳樟醇氢过氧化物的测试浓度为 1·0%。