Suppr超能文献

基于加速度计和跑步机的分析系统在测量健康成年人步态参数方面的比较。

Comparison of accelerometer-based and treadmill-based analysis systems for measuring gait parameters in healthy adults.

作者信息

Lim Seung-Yeop, Lee Wan-Hee

机构信息

Graduate School of Physical Therapy, Sahmyook University, Republic of Korea.

出版信息

J Phys Ther Sci. 2017 Apr;29(4):651-653. doi: 10.1589/jpts.29.651. Epub 2017 Apr 20.

Abstract

[Purpose] This study aimed to determine the correlation between accelerometer-based and treadmill-based analysis systems for measuring gait parameters during comfortable walking in healthy young adults. [Subjects and Methods] Twenty-three healthy adults participated in this study. Gait parameters were measured with simultaneous use of accelerometer-based and treadmill-based gait analysis systems, while participants walked for 30 s. [Results] There was a highly-significant correlation between the two systems with respect to cadence and velocity. The cadence, speed, and stride measured with the accelerometer system were significantly and highly correlated with the cadence, velocity, and number of steps measured with the treadmill-based system. The gait cycle duration measured with the accelerometer system was significantly and highly correlated with the step time and stride time measured with the treadmill-based gait system. [Conclusion] Gait analysis using an accelerometer system is a valid method for assessment of the effectiveness of therapeutic interventions in a clinical setting.

摘要

[目的]本研究旨在确定基于加速度计和基于跑步机的分析系统在测量健康年轻成年人舒适行走时步态参数之间的相关性。[对象与方法]23名健康成年人参与了本研究。在参与者行走30秒的过程中,同时使用基于加速度计和基于跑步机的步态分析系统测量步态参数。[结果]在步频和速度方面,两个系统之间存在高度显著的相关性。加速度计系统测量的步频、速度和步幅与基于跑步机的系统测量的步频、速度和步数显著且高度相关。加速度计系统测量的步态周期持续时间与基于跑步机的步态系统测量的步长时间和步幅时间显著且高度相关。[结论]在临床环境中,使用加速度计系统进行步态分析是评估治疗干预效果的有效方法。

相似文献

1
Comparison of accelerometer-based and treadmill-based analysis systems for measuring gait parameters in healthy adults.
J Phys Ther Sci. 2017 Apr;29(4):651-653. doi: 10.1589/jpts.29.651. Epub 2017 Apr 20.
2
Comparison between a center of mass and a foot pressure sensor system for measuring gait parameters in healthy adults.
J Phys Ther Sci. 2015 Oct;27(10):3199-202. doi: 10.1589/jpts.27.3199. Epub 2015 Oct 30.
4
Walking on a treadmill improves the stride length-cadence relationship in individuals with Parkinson's disease.
Gait Posture. 2019 Feb;68:136-140. doi: 10.1016/j.gaitpost.2018.11.025. Epub 2018 Nov 19.
5
Concurrent Validity of the Zeno Walkway for Measuring Spatiotemporal Gait Parameters in Older Adults.
J Geriatr Phys Ther. 2019 Jul/Sep;42(3):E42-E50. doi: 10.1519/JPT.0000000000000168.
6
Speed and temporal-distance adaptations during treadmill and overground walking following stroke.
Neurorehabil Neural Repair. 2005 Jun;19(2):115-24. doi: 10.1177/1545968305275286.
8
Effect of Backpack Strap Patterns on Gait Parameters in Young Adults at Self-Selected Normal and Fast Walking Speeds.
PM R. 2017 Jul;9(7):676-682. doi: 10.1016/j.pmrj.2016.10.010. Epub 2016 Oct 22.
10
Effect of bilateral subthalamic nucleus stimulation on gait in Parkinson's disease.
Brain. 2001 Aug;124(Pt 8):1590-600. doi: 10.1093/brain/124.8.1590.

引用本文的文献

1
Gait metrics analysis utilizing single-point inertial measurement units: a systematic review.
Mhealth. 2022 Jan 20;8:9. doi: 10.21037/mhealth-21-17. eCollection 2022.

本文引用的文献

1
Comparison between a center of mass and a foot pressure sensor system for measuring gait parameters in healthy adults.
J Phys Ther Sci. 2015 Oct;27(10):3199-202. doi: 10.1589/jpts.27.3199. Epub 2015 Oct 30.
2
Effects of gait velocity and center of mass acceleration during turning gait in old-old elderly women.
J Phys Ther Sci. 2015 Jun;27(6):1779-80. doi: 10.1589/jpts.27.1779. Epub 2015 Jun 30.
3
Gait analysis using wearable sensors.
Sensors (Basel). 2012;12(2):2255-83. doi: 10.3390/s120202255. Epub 2012 Feb 16.
4
Stroke rehabilitation.
Lancet. 2011 May 14;377(9778):1693-702. doi: 10.1016/S0140-6736(11)60325-5.
5
Concurrent validity of a trunk tri-axial accelerometer system for gait analysis in older adults.
Gait Posture. 2009 Apr;29(3):444-8. doi: 10.1016/j.gaitpost.2008.11.003. Epub 2008 Dec 12.
6
Test-retest reliability of trunk accelerometric gait analysis.
Gait Posture. 2004 Jun;19(3):288-97. doi: 10.1016/S0966-6362(03)00069-9.
7
Acceleration patterns of the head and pelvis when walking on level and irregular surfaces.
Gait Posture. 2003 Aug;18(1):35-46. doi: 10.1016/s0966-6362(02)00159-5.
10
Heel to toe motion characteristics in Parkinson patients during free walking.
Clin Biomech (Bristol). 2001 Nov;16(9):806-12. doi: 10.1016/s0268-0033(01)00069-9.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验