J Adhes Dent. 2017;19(3):267-275. doi: 10.3290/j.jad.a38437.
To examine the effect of reduced phosphoric acid pre-etching times on enamel fatigue bond strength of universal adhesives and surface characteristics by using atomic force microscopy (AFM).
Three universal adhesives were used in this study (Clearfil Universal Bond [C], G-Premio Bond [GP], Scotchbond Universal Adhesive [SU]). Four pre-etching groups were employed: enamel pre-etched with phosphoric acid and immediately rinsed with an air-water spray, and enamel pre-etched with phosphoric acid for 5, 10, or 15 s. Ground enamel was used as the control group. For the initial bond strength test, 15 specimens per etching group for each adhesive were used. For the shear fatigue test, 20 specimens per etching group for each adhesive were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred. Initial shear bond strengths and fatigue shear strengths of composite adhesively bonded to ground and pre-etched enamel were determined. AFM observations of ground and pre-etched enamel were also conducted, and surface roughness as well as surface area were evaluated.
The initial shear bond strengths and fatigue shear strengths of the universal adhesives in the pre-etched groups were significantly higher than those of the control group, and were not influenced by the pre-etching time. Significantly higher surface roughness and surface area of enamel surfaces in pre-etched groups were observed compared with those in the control group. While the surface area was not significantly influenced by etching time, surface roughness of the enamel surfaces in the pre-etched groups significantly increased with pre-etching time.
The results of this in vitro study suggest that reduced phosphoric acid pre-etching times do not impair the fatigue bond strength of universal adhesives. Although fatigue bond strength and surface area were not influenced by phosphoric-acid etching times, surface roughness increased with increasing etching time.
通过原子力显微镜(AFM)研究减少磷酸酸蚀时间对通用型粘结剂牙釉质疲劳粘结强度和表面特性的影响。
本研究使用了三种通用型粘结剂(Clearfil Universal Bond [C]、G-Premio Bond [GP]、Scotchbond Universal Adhesive [SU])。采用四种酸蚀组:磷酸酸蚀后立即用空气-水喷雾冲洗牙釉质,以及磷酸酸蚀 5、10 或 15 s 的牙釉质。研磨后的牙釉质为对照组。对于初始粘结强度测试,每种粘结剂的每个酸蚀组使用 15 个样本。对于剪切疲劳测试,每种粘结剂的每个酸蚀组使用 20 个样本,在 20 Hz 的正弦波下加载 50,000 次循环或直至发生故障。确定粘结到研磨和酸蚀牙釉质的复合粘结剂的初始剪切粘结强度和疲劳剪切强度。还对研磨和酸蚀牙釉质进行了 AFM 观察,并评估了表面粗糙度和表面积。
在酸蚀组中,通用粘结剂的初始剪切粘结强度和疲劳剪切强度明显高于对照组,且不受酸蚀时间的影响。与对照组相比,酸蚀组的牙釉质表面具有更高的表面粗糙度和表面积。虽然表面粗糙度随酸蚀时间的增加而显著增加,但表面积不受酸蚀时间的影响。
本体外研究结果表明,减少磷酸酸蚀时间不会降低通用粘结剂的疲劳粘结强度。尽管疲劳粘结强度和表面积不受磷酸酸蚀时间的影响,但表面粗糙度随酸蚀时间的增加而增加。