Lago Laura, da Silva Luis, Gude Francisco, Rilo Benito
Int J Oral Maxillofac Implants. 2017 Jul/Aug;32(4):919-926. doi: 10.11607/jomi.5859.
The aim of this prospective study was to evaluate radiographic levels of peri-implant bone crest as well as soft tissue response, papilla height, and buccal mucosa recession, in bone-level implants restored with platform switching after 1-year and 5-year follow-ups.
This prospective study called for the placement of 59 implants to obtain a target of 90% power. To compensate for possible dropouts, the sample size was adjusted to 67 implants. To assess marginal bone level changes, periapical radiographs were taken at baseline, 1 year, and 5 years after the definitive restorations. Peri-implant soft tissue modifications were evaluated by performing a photographic sequence at 15 days, 1 year, and 5 years after implant restoration. Parameters measured were: (1) distance from the tip of the papilla to the contact point and (2) apicocoronal crown length.
A one-way analysis of variance (ANOVA rank test) was used to compare quantitative data among the three time points studied. Mean marginal bone level changes were as follows: -0.06 ± 0.32 mm from baseline to 1 year, -0.23 ± 0.38 mm from 1 to 5 years, and -0.28 ± 0.45 mm from baseline to 5 years. In bone-level outcomes, no statistically significant differences were found between baseline and 1 year, while the mean differences between 1 and 5 years and baseline and 5 years showed statistically significant differences. In the soft tissue analysis, the distance from the tip of the papilla to the contact point showed the following values: baseline, 2.08 mm; 1 year, 1.54 mm; 5 years, 1.31 mm. No statistically significant differences were found between baseline and 1 year, whereas statistically significant differences between 1 and 5 years and baseline and 5 years were found. Apicocoronal crown length measurements showed the following values: baseline, 9.44 mm; 1 year, 9.28 mm; 5 years, 9.81 mm. No significant differences were found between times studied.
This prospective clinical study of 67 bone-level implants restored according to the platform-switching concept reported that radiographic levels of peri-implant bone crest were statistically significant between 1 and 5 years and baseline and 5 years. For the soft tissue response, the greatest reduction in the distance from the papilla to the contact point from 1 to 5 years and baseline to 5 years was observed. No significant differences were shown in the buccal margin.
本前瞻性研究旨在评估在采用平台转换技术修复的骨水平种植体1年和5年随访后,种植体周围骨嵴的影像学水平以及软组织反应、龈乳头高度和颊侧黏膜退缩情况。
本前瞻性研究需要植入59枚种植体以达到90%的检验效能目标。为补偿可能出现的失访情况,样本量调整为67枚种植体。为评估边缘骨水平变化,在最终修复后基线、1年和5年时拍摄根尖片。通过在种植体修复后15天、1年和5年进行摄影序列来评估种植体周围软组织的变化。测量的参数为:(1)龈乳头尖端至接触点的距离;(2)冠根向牙冠长度。
采用单因素方差分析(ANOVA秩和检验)比较所研究的三个时间点的定量数据。边缘骨水平的平均变化如下:从基线至1年为-0.06±0.32mm,从1年至5年为-0.23±0.38mm,从基线至5年为-0.28±0.45mm。在骨水平结果方面,基线与1年之间未发现统计学上的显著差异,而1年与5年之间以及基线与5年之间的平均差异显示出统计学上的显著差异。在软组织分析中,龈乳头尖端至接触点的距离显示如下数值:基线时为2.08mm;1年时为1.54mm;5年时为1.31mm。基线与1年之间未发现统计学上的显著差异,而1年与5年之间以及基线与5年之间发现了统计学上的显著差异。冠根向牙冠长度测量显示如下数值:基线时为9.44mm;1年时为9.28mm;5年时为9.81mm。在所研究的时间点之间未发现显著差异。
这项对67枚根据平台转换概念修复的骨水平种植体进行的前瞻性临床研究报告称,种植体周围骨嵴的影像学水平在1年与5年之间以及基线与5年之间具有统计学上的显著差异。对于软组织反应,观察到从1年至5年以及从基线至5年龈乳头至接触点的距离减少最为明显。颊侧边缘未显示出显著差异。