Suppr超能文献

多发性硬化症:与常规三维 T1 GRE 成像相比,三维 T1 黑血磁共振成像可提高对活跃性脑病变的检出率。

Multiple Sclerosis: Improved Detection of Active Cerebral Lesions With 3-Dimensional T1 Black-Blood Magnetic Resonance Imaging Compared With Conventional 3-Dimensional T1 GRE Imaging.

出版信息

Invest Radiol. 2018 Jan;53(1):13-19. doi: 10.1097/RLI.0000000000000410.

Abstract

OBJECTIVES

The aim of this study was to assess the diagnostic accuracy of a modified high-resolution whole-brain three-dimensional T1-weighted black-blood sequence (T1-weighted modified volumetric isotropic turbo spin echo acquisition [T1-mVISTA]) in comparison to a standard three-dimensional T1-weighted magnetization-prepared rapid gradient echo (MP-RAGE) sequence for detection of contrast-enhancing cerebral lesions in patients with relapsing-remitting multiple sclerosis (MS).

MATERIALS AND METHODS

After institutional review board approval and informed consent, 22 patients (8 men; aged 31.0 ± 9.2 years) with relapsing-remitting MS were included in this monocentric prospective cohort study.Contrast-enhanced T1-mVISTA and MP-RAGE, both with 0.8 mm resolution, were performed in all patients. In a substudy of 12 patients, T1-mVISTA was compared with a T1-mVISTA with 1.0 mm resolution (T1-mVISTA_1.0). Reference lesions were defined by an experienced neuroradiologist using all available sequences and served as the criterion standard. T1-mVISTA, T1-mVISTA_1.0, and MP-RAGE sequences were read in random order 4 weeks apart. Image quality, visual contrast enhancement, contrast-to-noise-ratio (CNR), diagnostic confidence, and lesion size were assessed and compared by Wilcoxon and Mann-Whitney U tests.

RESULTS

Eleven of 22 patients displayed contrast-enhancing lesions. Visual contrast enhancement, CNR, and diagnostic confidence of contrast-enhancing MS lesions were significantly increased in T1-mVISTA compared with MP-RAGE (P < 0.001). Significantly more contrast-enhancing lesions were detected with T1-mVISTA than with MP-RAGE (71 vs 39, respectively; P < 0.001). With MP-RAGE, 25.6% of lesions were missed in the initial reading, whereas only 4.2% of lesions were missed with T1-mVISTA. Increase of the voxel volume from 0.8 mm to 1.0 mm isotropic in T1-mVISTA_1.0 did not affect the detectability of lesions, whereas scan time was decreased from 4:43 to 1:55 minutes.

CONCLUSIONS

Three-dimensional T1-mVISTA improves the detection rates of contrast-enhancing cerebral MS lesions compared with conventional 3D MP-RAGE sequences by increasing CNR of lesions and might, therefore, be useful in patient management.

摘要

目的

本研究旨在评估改良高分辨率全脑三维 T1 加权黑血序列(T1 加权容积各向同性涡轮自旋回波采集 [T1-mVISTA])与标准三维 T1 加权磁化准备快速梯度回波(MP-RAGE)序列在检测复发缓解型多发性硬化症(MS)患者对比增强脑病变中的诊断准确性。

材料与方法

经机构审查委员会批准和知情同意后,纳入 22 例(8 例男性;年龄 31.0±9.2 岁)复发缓解型 MS 患者进行这项单中心前瞻性队列研究。所有患者均行对比增强 T1-mVISTA 和 MP-RAGE 检查,两者分辨率均为 0.8mm。在 12 例患者的子研究中,T1-mVISTA 与分辨率为 1.0mm(T1-mVISTA_1.0)的 T1-mVISTA 进行比较。由一位有经验的神经放射科医生使用所有可用序列定义参考病变,并作为金标准。T1-mVISTA、T1-mVISTA_1.0 和 MP-RAGE 序列在 4 周后以随机顺序分别阅读。通过 Wilcoxon 和 Mann-Whitney U 检验评估并比较图像质量、视觉对比增强、对比噪声比(CNR)、诊断信心和病变大小。

结果

22 例患者中有 11 例显示对比增强病变。与 MP-RAGE 相比,T1-mVISTA 中增强 MS 病变的视觉对比增强、CNR 和诊断信心显著增加(P<0.001)。与 MP-RAGE 相比,T1-mVISTA 检测到的增强病变更多(分别为 71 个和 39 个;P<0.001)。使用 MP-RAGE 初始读片时,有 25.6%的病变漏诊,而 T1-mVISTA 仅漏诊 4.2%的病变。在 T1-mVISTA_1.0 中,将体素体积从 0.8mm 增加到 1.0mm 各向同性并未影响病变的可检测性,而扫描时间从 4:43 减少到 1:55 分钟。

结论

与传统的三维 MP-RAGE 序列相比,三维 T1-mVISTA 通过增加病变的 CNR 提高了对比增强脑 MS 病变的检出率,因此可能有助于患者管理。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验