Suppr超能文献

来自供体眼中提取的人工晶状体的光散射水平。

Light scattering levels from intraocular lenses extracted from donor eyes.

机构信息

From the Rotterdam Ophthalmic Institute (Łabuz), Rotterdam, the Department of Ophthalmology (Reus), Amphia Hospital, Breda, and the Netherlands Institute for Neuroscience (van den Berg), Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands.

From the Rotterdam Ophthalmic Institute (Łabuz), Rotterdam, the Department of Ophthalmology (Reus), Amphia Hospital, Breda, and the Netherlands Institute for Neuroscience (van den Berg), Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands.

出版信息

J Cataract Refract Surg. 2017 Sep;43(9):1207-1212. doi: 10.1016/j.jcrs.2017.06.044.

Abstract

PURPOSE

To assess light scatter levels of intraocular lenses (IOLs) extracted from donor eyes to understand straylight elevation documented earlier in pseudophakic population studies and identify potential sources of light scattering in IOLs.

SETTING

Rotterdam Ophthalmic Institute, Rotterdam, the Netherlands.

DESIGN

Experimental study.

METHODS

Light scattering in 74 donor IOLs was measured with the C-Quant device adapted for in vitro analysis of IOLs. Straylight was assessed at a 2.5-degree and 7.0-degree scatter angle, and results were compared with the straylight of a 20-year-old crystalline lens, a 70-year-old crystalline lens, and a lens with cataract. To identify potential changes to the IOL material, the IOLs were examined with a light microscope and a slitlamp.

RESULTS

At 2.5 degrees and 7.0 degrees, the straylight parameter was 5.78 deg/steradian (sr) ± 4.70 (SD) and 5.06 ± 4.01 deg/sr, respectively. Forty-one percent of IOLs showed lower straylight than the 20-year-old lens. In 14%, the scattering intensity was higher than in the 70-year-old lens; none showed straylight comparable to that of the cataractous lens. Increased straylight was associated with surface deposits, snowflake-like degeneration, and glistenings. The incidence of IOL-related complications differed between the IOL groups.

CONCLUSIONS

Microscopic structural alterations of IOLs play a major role in straylight elevations in pseudophakic eyes. A clear correlation with degeneration and/or alteration of implanted IOLs was found. Although these IOL-related complications would likely not affect visual acuity, they give rise to straylight and thus can cause disability glare and other symptoms.

摘要

目的

评估从供体眼中提取的人工晶状体 (IOL) 的光散射水平,以了解先前在人工晶状体眼人群研究中记录到的杂散光增加,并确定 IOL 中潜在的光散射源。

地点

荷兰鹿特丹眼科研究所。

设计

实验研究。

方法

使用 C-Quant 设备测量 74 个供体 IOL 的光散射,该设备经过改编,可用于体外分析 IOL。在 2.5 度和 7.0 度散射角评估杂散光,并将结果与 20 岁晶状体、70 岁晶状体和白内障晶状体的杂散光进行比较。为了确定 IOL 材料的潜在变化,用显微镜和裂隙灯检查 IOL。

结果

在 2.5 度和 7.0 度时,杂散光参数分别为 5.78 度/斯特拉德(sr)±4.70(SD)和 5.06±4.01 deg/sr。41%的 IOL 显示的杂光低于 20 岁晶状体。在 14%的情况下,散射强度高于 70 岁晶状体;没有一个显示出与白内障晶状体相当的杂散光。杂散光增加与表面沉积物、雪花状变性和闪光有关。IOL 相关并发症的发生率在不同的 IOL 组之间存在差异。

结论

IOL 的微观结构改变在人工晶状体眼的杂散光增加中起主要作用。发现与植入的 IOL 的变性和/或改变有明显的相关性。虽然这些与 IOL 相关的并发症可能不会影响视力,但它们会产生杂散光,从而导致眩光和其他症状。