BACKGROUND

Dehydration in older patients has long been considered a significant health problem because it implies increased morbidity and mortality. However, dehydration is detected by a combination of physical signs and blood tests. For older people dwelling at home and in nursing homes, a simple and non-invasive method for detecting dehydration by caregivers is needed. The total body resistance is measured using bioelectrical impedance analysis and is known as an indicator of dehydration. There are no data from older Japanese patients on this issue. We performed this study to examine the relationship between dehydration and total body resistance in Japan.

METHODS

We performed blood tests and measured bioelectrical impedance in older outpatients aged ≥ 65 years from the Internal Medicine Department at Mito Kyodo General Hospital. Patients were classified as dehydrated and non-dehydrated using the dehydration index with a blood urea nitrogen/creatinine ratio > 20, and the mean total body resistance was compared between the two groups.

RESULTS

Eighty-one patients were recruited in the study. In the dehydrated group, the mean total body resistance was 439 Ω at 50 kHz, which was significantly higher than that in the non-dehydrated group (408 Ω, P = 0.038).

CONCLUSIONS

The total body resistance measurements can be used for simple assessment of dehydration among older Japanese patients.

摘要

背景

老年患者的脱水长期以来一直被视为一个重大的健康问题,因为这意味着发病率和死亡率的增加。然而,脱水是通过体征和血液检查相结合来检测的。对于居家和养老院中的老年人,护理人员需要一种简单且无创的脱水检测方法。全身电阻通过生物电阻抗分析进行测量,是脱水的一个指标。关于这个问题,尚无来自日本老年患者的数据。我们开展这项研究以探讨日本人群中脱水与全身电阻之间的关系。

方法

我们对水户协同综合医院内科年龄≥65岁的老年门诊患者进行了血液检查并测量了生物电阻抗。使用血尿素氮/肌酐比值>20的脱水指数将患者分为脱水组和非脱水组,并比较两组的平均全身电阻。

结果

该研究共纳入81例患者。在脱水组中,50kHz时的平均全身电阻为439Ω,显著高于非脱水组(408Ω,P=0.038)。

结论

全身电阻测量可用于对日本老年患者的脱水情况进行简单评估。

相似文献

2
Validation of multi-frequency bioelectrical impedance analysis in detecting changes in fluid balance of geriatric patients.
J Am Geriatr Soc. 1997 Nov;45(11):1345-51. doi: 10.1111/j.1532-5415.1997.tb02934.x.
3
Is this elderly patient dehydrated? Diagnostic accuracy of hydration assessment using physical signs, urine, and saliva markers.
J Am Med Dir Assoc. 2015 Mar;16(3):221-8. doi: 10.1016/j.jamda.2014.09.012. Epub 2014 Oct 22.
5
Hydration in older adults: the contribution of bioelectrical impedance analysis.
Int J Speech Lang Pathol. 2014 Jun;16(3):273-81. doi: 10.3109/17549507.2014.882989. Epub 2014 Feb 13.
8
Association of Bioelectrical Impedance Analysis-Derived Phase Angle and Sarcopenia in Older Adults.
Nutr Clin Pract. 2017 Feb;32(1):103-109. doi: 10.1177/0884533616664503. Epub 2016 Sep 25.

引用本文的文献

本文引用的文献

5
Prevalence, risk factors and strategies to prevent dehydration in older adults.
Contemp Nurse. 2008 Dec;31(1):44-56. doi: 10.5172/conu.673.31.1.44.
6
High prevalence of plasma hypertonicity among community-dwelling older adults: results from NHANES III.
J Am Diet Assoc. 2005 Aug;105(8):1231-9. doi: 10.1016/j.jada.2005.05.003.
8
The rational clinical examination. Is this patient hypovolemic?
JAMA. 1999 Mar 17;281(11):1022-9. doi: 10.1001/jama.281.11.1022.
9
Axillary sweating in clinical assessment of dehydration in ill elderly patients.
BMJ. 1994 May 14;308(6939):1271. doi: 10.1136/bmj.308.6939.1271.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验