Department of Molecular Imaging and Nuclear Medicine and Key Laboratory of Cancer Prevention and Therapy and Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin 300060, China.
PET Center of Xuan Wu Hospital, Capital Medical University, Beijing, China.
Contrast Media Mol Imaging. 2017 Jul 3;2017:5438395. doi: 10.1155/2017/5438395. eCollection 2017.
To compare the diagnostic performance of three-dimensional (3D) positron emission mammography (PEM) versus whole body positron emission tomography (WBPET) for breast cancer.
A total of 410 women with normal breast or benign or highly suspicious malignant tumors were randomized at 1 : 1 ratio to undergo 3D-PEM followed by WBPET or WBPET followed by 3D-PEM. Lumpectomy or mastectomy was performed on eligible participants after the scanning.
The sensitivity and specificity of 3D-PEM were 92.8% and 54.5%, respectively. WBPET showed a sensitivity of 95.7% and specificity of 56.8%. After exclusion of the patients with lesions beyond the detecting range of the 3D-PEM instrument, 3D-PEM showed higher sensitivity than WBPET (97.0% versus 95.5%, = 0.913), particularly for small lesions (<1 cm) (72.0% versus 60.0%, = 0.685).
The 3D-PEM appears more sensitive to small lesions than WBPET but may fail to detect lesions that are beyond the detecting range. This study was approved by the Ethics Committee (E2012052) at the Tianjin Medical University Cancer Institute and Hospital (Tianjin, China). The instrument positron emission mammography (PEMi) was approved by China State Food and Drug Administration under the registration number 20153331166.
比较三维正电子发射乳腺断层成像术(3D-PEM)与全身正电子发射断层扫描术(WBPET)对乳腺癌的诊断性能。
410 名乳腺正常或良性或高度疑似恶性肿瘤的女性患者,以 1:1 的比例随机分为两组,一组先进行 3D-PEM 检查,然后进行 WBPET 检查,另一组先进行 WBPET 检查,然后进行 3D-PEM 检查。扫描后,对符合条件的参与者进行肿块切除术或乳房切除术。
3D-PEM 的敏感性和特异性分别为 92.8%和 54.5%。WBPET 的敏感性为 95.7%,特异性为 56.8%。排除 3D-PEM 仪器检测范围之外的患者后,3D-PEM 的敏感性高于 WBPET(97.0%比 95.5%, = 0.913),尤其是对于小病灶(<1cm)(72.0%比 60.0%, = 0.685)。
3D-PEM 对小病灶的敏感性高于 WBPET,但可能无法检测到超出检测范围的病灶。本研究经天津医科大学肿瘤医院伦理委员会(E2012052)批准(中国天津)。正电子发射乳腺断层成像仪(PEMi)获中国国家食品药品监督管理总局批准,注册号为 20153331166。