Laser scanning in vivo confocal microscopy (IVCM) for evaluating human corneal sub-basal nerve plexus parameters: protocol for a systematic review.

机构信息

Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia.

Centre for Epidemiology and Biostatistics, Melbourne School of Population and Global Health, The University of Melbourne, Parkville, Victoria, Australia.

出版信息

BMJ Open. 2017 Nov 3;7(11):e018646. doi: 10.1136/bmjopen-2017-018646.

Abstract

INTRODUCTION

Laser scanning in vivo confocal microscopy (IVCM) enables non-invasive, high-resolution imaging of the cornea. In recent years, there has been a vast increase in researchers using laser scanning IVCM to image and quantify corneal nerve parameters. However, a range of methodological approaches have been adopted. The primary aim of this systematic review is to critically appraise the reported method(s) of primary research studies that have used laser scanning IVCM to quantify corneal sub-basal nerve plexus (SBNP) parameters in humans, and to examine corneal nerve parameters in healthy individuals.

METHODS AND ANALYSIS

A systematic review of primary studies that have used laser scanning IVCM to quantify SBNP parameters in humans will be conducted. Comprehensive electronic searches will be performed in Ovid MedLine, Embase and the Cochrane Library. Two reviewers will independently assess titles and abstracts, and exclude studies not meeting the inclusion criteria. For studies judged eligible or potentially eligible, full texts will be independently assessed by two reviewers to determine eligibility. A third reviewer will resolve any discrepancies in judgement. Risk of bias will be assessed using a custom tool, covering five methodological domains: participant selection, method of image capture, method of image analysis, data reporting and other sources of bias. A systematic narrative synthesis of findings will be provided. A multilevel random-effects meta-analysis will be performed for corneal nerve parameters derived from healthy participants. This review will be reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement.

ETHICS AND DISSEMINATION

As this review considers published data, ethical approval is not required. We foresee that this synthesis will serve as a reference for future studies, and can be used to inform best practice standards for using IVCM in clinical research. A manuscript reporting the results of the review will be published and may also be presented at scientific conferences.

摘要

简介

激光共聚焦显微镜(IVCM)活体扫描可实现对角膜的非侵入性、高分辨率成像。近年来,越来越多的研究人员使用激光共聚焦 IVCM 来对角膜神经参数进行成像和量化。然而,各种方法已被采用。本系统评价的主要目的是批判性地评估使用激光共聚焦 IVCM 对人体角膜下神经丛(SBNP)参数进行量化的主要研究报告中所采用的方法,并检查健康个体的角膜神经参数。

方法和分析

将对使用激光共聚焦 IVCM 对人体 SBNP 参数进行量化的主要研究进行系统评价。将在 Ovid MedLine、Embase 和 Cochrane 图书馆中进行全面的电子检索。两位评审员将独立评估标题和摘要,并排除不符合纳入标准的研究。对于被判断为符合或潜在符合条件的研究,将由两位评审员独立评估全文,以确定是否符合条件。任何判断上的分歧将由第三位评审员解决。将使用涵盖五个方法学领域的定制工具评估偏倚风险:参与者选择、图像采集方法、图像分析方法、数据报告和其他偏倚源。将提供对研究结果的系统叙述性综合。将对来自健康参与者的角膜神经参数进行多层次随机效应荟萃分析。本综述将按照系统评价和荟萃分析的首选报告项目进行报告。

伦理和传播

由于本综述考虑了已发表的数据,因此不需要伦理批准。我们预计,这项综合研究将成为未来研究的参考,并可用于为在临床研究中使用 IVCM 提供最佳实践标准。一份报告综述结果的手稿将被发表,并可能在科学会议上进行展示。

相似文献

引用本文的文献

1
Non-contact confocal calcium imaging of murine corneal nerves.小鼠角膜神经的非接触共聚焦钙成像
Biomed Opt Express. 2024 Dec 3;16(1):1-11. doi: 10.1364/BOE.543333. eCollection 2025 Jan 1.

本文引用的文献

10
Corneal nerves in health and disease.健康与疾病状态下的角膜神经
Surv Ophthalmol. 2014 May-Jun;59(3):263-85. doi: 10.1016/j.survophthal.2013.09.002. Epub 2014 Jan 23.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验