To assess the safety and effects on motor cortex excitability of five cathodal-tDCS sessions (charge density 342.9C/m) delivered over the dominant motor cortex with a return electrode over the ipsilateral shoulder at increasing time intervals in 25hours.
Safety was operatively defined as absence of serious adverse events related to tDCS including brain tissue alterations documentable by magnetic resonance imaging and spectroscopy. Effects on motor cortex excitability were evaluated by motor evoked potential (MEP) amplitude.
Thirty-two healthy subjects were enrolled. No serious adverse events occurred. Magnetic resonance imaging and spectroscopy did not show alterations. Inter-individual MEP variability was assessed by the standard error of mean at baseline and subjects were classified on the basis of the ratio between normalized MEPs after the first stimulation compared to baseline. Fifty-six percent of subjects responded with reduction of MEP amplitude, 25% were non-responders and 19% were inverse responders. In responders, MEP suppression was 32% one hour after the end of first cathodal-tDCS, 21% three hours after the second, no longer present with increasing stimulation intervals and 38% two and half hours after the fifth stimulation. Intra-individual inter-sessional reliability in response was high (88-92%).
Five cathodal-tDCS sessions in 25hours are safe. Inter-individual variability in MEP suppression is considerable but response to one cathodal-tDCS highly predicts the response to other sessions. Duration of MEP suppression is limited to three hours. These findings should be considered in trials utilizing repeated cathodal-tDCS.
评估在 25 小时内以 25 小时的时间间隔递增,在优势运动皮层上用返回电极置于同侧肩部,对大脑皮层进行五次阴极 tDCS(电荷密度 342.9C/m)治疗的安全性和对运动皮层兴奋性的影响。
安全性通过磁共振成像和光谱学记录的 tDCS 相关的严重不良事件(脑组织改变)的缺失来明确。运动诱发电位(MEP)振幅评估运动皮层兴奋性的变化。
共纳入 32 名健康受试者。未发生严重不良事件。磁共振成像和光谱学未显示改变。通过在基线时的均数标准误差评估个体间 MEP 变异性,并根据第一次刺激后的归一化 MEP 与基线的比值对受试者进行分类。56%的受试者 MEP 振幅降低,25%的受试者无反应,19%的受试者为反向反应。在反应者中,第一次阴极 tDCS 结束后 1 小时 MEP 抑制为 32%,第二次 3 小时后为 21%,随着刺激间隔的增加而不再存在,第五次刺激后 2 个半小时为 38%。反应的个体内组间可靠性很高(88-92%)。
25 小时内进行五次阴极 tDCS 是安全的。MEP 抑制的个体间变异性很大,但对一次阴极 tDCS 的反应高度预测了对其他治疗的反应。MEP 抑制的持续时间限于 3 小时。这些发现应在重复使用阴极 tDCS 的试验中加以考虑。