Fallah Karkan Morteza, Ghiasy Saleh, Ranjbar Arash, Javanmard Babak
Laser Application in Medical Science Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
J Lasers Med Sci. 2018 Winter;9(1):69-72. doi: 10.15171/jlms.2018.14. Epub 2017 Dec 26.
Presently, different holmium: yttrium aluminum garnet (Ho:YAG) laser calibers are used for endoscopic stone treatment, which include 200, 365, 500 and 1000 Mm fibers. Currently, there are not enough studies to compare the performance of these fibers. In this retrospective investigation, we compared the outcome of 200, 365 and 500 Mm fibers of Ho:YAG laser in transurethral lithotripsy of ureteral stone. From January 2016 to June 2017, 74 subjects with mean age of 35.3 ± 5.6 were randomly allocated to 3 groups according to the caliber of laser, 200, 365 and 500 Mm for transurethral lithotripsy. The main purpose of this investigation was to evaluate mean operation time (MOT), stone free rate (SFR) and complications. MOT and SFR were significantly different in 500 Mm laser caliber (=0.046, =0.029, respectively). There was no remarkable difference between the 3 groups in this regard. Based upon our data, the clinical potency of the Ho: YAG laser was great in all 3 fiber calibers. The most important results of this comparison were the significantly higher SFR with increased laser caliber.
目前,不同口径的钬:钇铝石榴石(Ho:YAG)激光用于内镜下结石治疗,其中包括200、365、500和1000微米的光纤。目前,尚无足够的研究来比较这些光纤的性能。在这项回顾性研究中,我们比较了Ho:YAG激光200、365和500微米光纤在输尿管结石经尿道碎石术中的治疗效果。2016年1月至2017年6月,74名平均年龄为35.3±5.6岁的受试者根据激光口径被随机分为3组,分别采用200、365和500微米光纤进行经尿道碎石术。本研究的主要目的是评估平均手术时间(MOT)、结石清除率(SFR)和并发症。500微米激光口径的MOT和SFR有显著差异(分别为P=0.046,P=0.029)。在这方面,3组之间没有显著差异。根据我们的数据,Ho:YAG激光在所有3种光纤口径中的临床效能都很高。本次比较最重要的结果是随着激光口径增大,SFR显著提高。