Abstract

INTRODUCTION

Endodontic rotary systems may result in dentinal cracks. They may propagate to vertical root fracture that compromises the outcome of endodontic treatment. This study aimed to compare Neolix and Reciproc (single-file systems), Mtwo and ProTaper (conventional rotary systems) in terms of dentinal crack formation in root canal walls.

METHODS AND MATERIALS

This study was conducted on 110 extracted human single-rooted teeth. The teeth were randomly divided into four experimental groups (=25) for root canal preparation with Neolix, Reciproc, Mtwo and ProTaper systems and two control groups (=5). The first control group underwent root canal instrumentation with hand files while the second control group received no preparation and was only irrigated. After instrumentation, root canals were horizontally sectioned at 3, 6 and 9 mm from the apex and inspected under a stereomicroscope under 12× magnification for detection of cracks. The data were analyzed using GEE test and Bonferroni tests (<0.05).

RESULTS

No crack was found in the control groups. All rotary systems caused dentinal cracks. ProTaper, Reciproc, Mtwo and Neolix caused cracks in 92%, 80%, 68% and 48% of samples. ProTaper caused significantly more cracks than Neolix and Mtwo (<0.05). No significant differences were noted between other groups (>0.05).

CONCLUSION

All rotary systems cause dentinal cracks and it is significantly different in apical, middle and coronal third of the root. Neolix appears to be a suitable alternative to other rotary systems since use of this single-file system saves time and cost and minimizes trauma to dentinal walls.

摘要

引言

根管旋转系统可能导致牙本质裂纹。这些裂纹可能会扩展为垂直根折,从而影响根管治疗的效果。本研究旨在比较Neolix和Reciproc(单根管系统)、Mtwo和ProTaper(传统旋转系统)在根管壁牙本质裂纹形成方面的差异。

方法和材料

本研究使用了110颗拔除的人类单根牙。将牙齿随机分为四组实验组(每组25颗),分别用Neolix、Reciproc、Mtwo和ProTaper系统进行根管预备,另有两组对照组(每组5颗)。第一对照组用手用锉进行根管预备,第二对照组不做预备,仅进行冲洗。预备完成后,在距根尖3、6和9毫米处将根管水平切片,在体视显微镜下以12倍放大倍数检查裂纹。数据采用广义估计方程(GEE)检验和Bonferroni检验进行分析(<0.05)。

结果

对照组未发现裂纹。所有旋转系统均导致牙本质裂纹。ProTaper、Reciproc、Mtwo和Neolix导致裂纹的样本比例分别为92%、80%、68%和48%。ProTaper导致的裂纹明显多于Neolix和Mtwo(<0.05)。其他组之间未发现显著差异(>0.05)。

结论

所有旋转系统均会导致牙本质裂纹,且在根尖、根中和冠方三分之一处存在显著差异。Neolix似乎是其他旋转系统的合适替代品,因为使用这种单根管系统可节省时间和成本,并将对牙本质壁的创伤降至最低。