Opt Lett. 2018 May 15;43(10):2280-2283. doi: 10.1364/OL.43.002280.
In this Letter, we demonstrate the possibility to measure the refractive index of a liquid, using the stimulating Brillouin scattering in a 3-cm-long side-polished optical fiber. In addition, we show that by depositing a high-refractive index layer on the polished surface the sensitivity of the Brillouin frequency shift (BFS) can be increased due to a higher penetration of the evanescent field in the outer medium. Experiments show a maximum BFS change of about 11 MHz when varying the refractive index of the external medium from 1 (air) to 1.402, and a BFS sensitivity to refractive index of about 293 MHz/RIU around 1.40.
在这封信中,我们展示了使用 3 厘米长的侧边抛光光纤中的受激布里渊散射来测量液体折射率的可能性。此外,我们还表明,通过在抛光表面上沉积高折射率层,可以由于外部介质中的消逝场的更高穿透而增加布里渊频移(BFS)的灵敏度。实验表明,当外部介质的折射率从 1(空气)变化到 1.402 时,BFS 的最大变化约为 11 MHz,而在 1.40 附近,BFS 对折射率的灵敏度约为 293 MHz/RIU。