Suppr超能文献

成人肘关节测角法测量的可靠性和有效性:文献系统评价

The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature.

作者信息

van Rijn Suzanne F, Zwerus Elisa L, Koenraadt Koen Lm, Jacobs Wilco Ch, van den Bekerom Michel Pj, Eygendaal Denise

机构信息

Orthopedic Surgery Department, Amphia Hospital, Breda, the Netherlands.

Department of Orthopedic Surgery, Academic Medical Centre, Amsterdam, the Netherlands.

出版信息

Shoulder Elbow. 2018 Oct;10(4):274-284. doi: 10.1177/1758573218774326. Epub 2018 Jun 3.

Abstract

BACKGROUND

The universal goniometer is a simple measuring tool. With this review we aimed to investigate the reliability and validity of the universal goniometer in measurements of the adults' elbow.

METHODS

Preferred Reporting Items for Systematic reviews and Meta-Analysis guidelines were followed and our study protocol was published online at PROSPERO. A literature search was conducted on relevant studies. Methodological quality was assessed using the Quality Appraisal of Diagnostic Reliability (QAREL) scoring system.

RESULTS

Out of 697 studies yielded from our literature search, 12 were included. Six studies were rated as high quality. The intrarater reliability intraclass correlation coefficient ranged from 0.45 to 0.99, the interrater reliability ranged from intraclass correlation coefficient 0.53-0.97. One study providing instructions on goniometric alignment did not find a difference in expert versus non-expert examiners. Another study in which examiners were not instructed found a higher interrater reliability in expert examiners. One study investigating the validity of the goniometer in elbow measurements found a maximum standard error of the mean of 11.5° for total range of motion.

DISCUSSION

Overall, the studies showed high intra- and interrater reliability of the universal goniometer. The reliability of the universal goniometer in non-expert examiners can be increased by clear instructions on goniometric alignment.

摘要

背景

通用测角仪是一种简单的测量工具。通过本综述,我们旨在研究通用测角仪在测量成人肘部时的可靠性和有效性。

方法

遵循系统评价和Meta分析的首选报告项目指南,我们的研究方案已在PROSPERO上在线发表。对相关研究进行了文献检索。使用诊断可靠性质量评估(QAREL)评分系统评估方法学质量。

结果

在我们的文献检索得出的697项研究中,纳入了12项。六项研究被评为高质量。评估者内信度组内相关系数范围为0.45至0.99,评估者间信度组内相关系数范围为0.53 - 0.97。一项提供测角仪对准说明的研究未发现专家与非专家检查者之间存在差异。另一项未对检查者进行指导的研究发现专家检查者的评估者间信度更高。一项研究测角仪在肘部测量中的有效性的研究发现,总活动范围的平均最大标准误差为11.5°。

讨论

总体而言,研究表明通用测角仪具有较高的评估者内和评估者间信度。通过对测角仪对准进行清晰说明,可以提高通用测角仪在非专家检查者中的可靠性。

相似文献

1
The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature.
Shoulder Elbow. 2018 Oct;10(4):274-284. doi: 10.1177/1758573218774326. Epub 2018 Jun 3.
5
Validity of goniometric elbow measurements: comparative study with a radiographic method.
Clin Orthop Relat Res. 2011 Nov;469(11):3134-40. doi: 10.1007/s11999-011-1986-8. Epub 2011 Jul 21.
9
Validity and Reliability of 2 Goniometric Mobile Apps: Device, Application, and Examiner Factors.
J Sport Rehabil. 2016 Dec;25(4):371-379. doi: 10.1123/jsr.2015-0041. Epub 2016 Aug 24.
10
Reliability of shoulder range of motion comparing a goniometer to a digital level.
Physiother Theory Pract. 2010 Jul;26(5):327-33. doi: 10.3109/09593980903094230.

引用本文的文献

1
Comparison of Carrying Angle of Elbow between Patients with and without Lateral Epicondylitis: An Observational Study.
JNMA J Nepal Med Assoc. 2025 Jan;63(281):52-56. doi: 10.31729/jnma.8863. Epub 2025 Jan 31.
2
Casting vs Surgical Treatment of Children With Medial Epicondyle Fractures: A Randomized Clinical Trial.
JAMA Netw Open. 2025 May 1;8(5):e258479. doi: 10.1001/jamanetworkopen.2025.8479.
3
Neuromuscular electrical stimulation producing low evoked force elicits the repeated bout effect on muscle damage markers of the elbow flexors.
Sports Med Health Sci. 2024 Apr 25;7(2):124-131. doi: 10.1016/j.smhs.2024.04.006. eCollection 2025 Mar.
7
Acute effects of muscle vibration on elbow joint position sense in healthy young men: A randomized trial.
Medicine (Baltimore). 2023 Sep 8;102(36):e35017. doi: 10.1097/MD.0000000000035017.
8
Assessment of shoulder range of motion using a commercially available wearable sensor-a validation study.
Mhealth. 2022 Oct 30;8:30. doi: 10.21037/mhealth-22-7. eCollection 2022.
9
The Management of Valgus Extension Overload Syndrome Experienced with Hitting in a High School Baseball Player: A Case Report.
Int J Sports Phys Ther. 2022 Oct 1;17(6):1156-1169. doi: 10.26603/001c.38168. eCollection 2022.

本文引用的文献

1
Normative values and affecting factors for the elbow range of motion.
Shoulder Elbow. 2019 Jun;11(3):215-224. doi: 10.1177/1758573217728711. Epub 2017 Sep 11.
3
A Comparison of Elbow Range of Motion Measurements: Smartphone-Based Digital Photography Versus Goniometric Measurements.
J Hand Surg Am. 2016 Apr;41(4):510-515.e1. doi: 10.1016/j.jhsa.2016.01.006. Epub 2016 Feb 13.
6
Validation of an innovative method of shoulder range-of-motion measurement using a smartphone clinometer application.
J Shoulder Elbow Surg. 2014 Nov;23(11):e275-82. doi: 10.1016/j.jse.2014.02.030. Epub 2014 Jun 9.
7
Inter-clinician and intra-clinician reliability of force application during joint mobilization: a systematic review.
Man Ther. 2014 Apr;19(2):90-6. doi: 10.1016/j.math.2013.12.003. Epub 2013 Dec 24.
8
Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: a systematic review.
Man Ther. 2014 Feb;19(1):10-7. doi: 10.1016/j.math.2013.09.003. Epub 2013 Oct 26.
9
The reliability of a quality appraisal tool for studies of diagnostic reliability (QAREL).
BMC Med Res Methodol. 2013 Sep 9;13:111. doi: 10.1186/1471-2288-13-111.
10
Reliability of a smartphone-based goniometer for knee joint goniometry.
Int J Rehabil Res. 2013 Jun;36(2):146-51. doi: 10.1097/MRR.0b013e32835b8269.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验