Mitchell K T, Ferrell J E, Huestis W H
Anal Biochem. 1986 Nov 1;158(2):447-53. doi: 10.1016/0003-2697(86)90574-9.
A simple, rapid, two-dimensional TLC system is presented which resolves the four phosphoinositide cycle phospholipids as well as all commonly encountered major and minor phospholipids. Ca2+-free lipid samples are loaded onto silica gel HL plates and developed first in 48:40:7:5 chloroform:methanol:water:concentrated ammonia, and then in 55:25:5 chloroform:methanol:formic acid. The method was applied successfully to human erythrocytes, human platelets, and BL/VL3 murine lymphoma cells.
本文介绍了一种简单、快速的二维薄层层析系统,该系统可分离四种磷酸肌醇循环磷脂以及所有常见的主要和次要磷脂。将不含Ca2+的脂质样品加载到硅胶HL板上,首先在氯仿:甲醇:水:浓氨水(48:40:7:5)中展开,然后在氯仿:甲醇:甲酸(55:25:5)中展开。该方法已成功应用于人类红细胞、人类血小板和BL/VL3小鼠淋巴瘤细胞。