利用迟脉波预防对肾移植可能产生的毒性作用。

Prevention of Possible Toxic Effects on the Kidney Graft with Parvus Tardus Waveform.

作者信息

Trnacevic Senaid, Nislic Edin, Begic Edin, Trnacevic Emir, Begic Nedim, Tulumovic Emir, Dobraca Amra

机构信息

Department of Internal Medicine, Faculty of Medicine, University of Tuzla, Tuzla, Bosnia and Herzegovina.

Department of Eye Diseases, Cantonal Hospital Orasje, Orasje, Bosnia and Herzegovina.

出版信息

Int J Prev Med. 2018 Aug 30;9:76. doi: 10.4103/ijpvm.IJPVM_478_17. eCollection 2018.

Abstract

The aim of this study was to present a patient (acute allograft dysfunction after a kidney transplantation) with previously detected minimum plaque on both iliac arteries by scintigram and afterward a pathological Color Doppler Ultrasound (CDU) record and to point on possibility of avoiding toxic computed tomography (CT) angiography in certain renal graft recipients. Ultrasound (US) findings showed normal graft size, whereas Doppler signals detected parvus-tardus waveforms pointing to arterial stenosis. Isotope perfusion scintigraphy registered a slow flow on both iliac arteries and normal graft perfusion. CT angiography has not been performed because of the possible toxic effects to the graft. We believe that favorable clinical and biochemical findings along with US and isotope ratio monitoring are sufficient to avoid CT contrast angiography.

摘要

本研究的目的是呈现一名患者(肾移植后急性移植物功能障碍),其通过闪烁扫描先前在双侧髂动脉检测到最小斑块,随后有病理彩色多普勒超声(CDU)记录,并指出在某些肾移植受者中避免使用有潜在毒性的计算机断层扫描(CT)血管造影的可能性。超声(US)检查结果显示移植肾大小正常,而多普勒信号检测到小慢波波形,提示动脉狭窄。同位素灌注闪烁扫描显示双侧髂动脉血流缓慢,移植肾灌注正常。由于对移植物可能产生毒性作用,未进行CT血管造影。我们认为,良好的临床和生化检查结果以及超声和同位素比值监测足以避免CT造影血管造影。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6ad1/6177530/2d93cb492ffc/IJPVM-9-76-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验