Parnia Feridoun, Yazdani Javad, Fakour Parisa, Mahboub Farhang, Vahid Pakdel Seyyed Mahdi
Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
Department of Prosthodontics, Tabriz University of Medical Sciences, Tabriz, Iran.
J Dent Res Dent Clin Dent Prospects. 2018 Summer;12(3):190-195. doi: 10.15171/joddd.2018.029. Epub 2018 Sep 18.
Dental implants are utilized with an ever-increasing rate. One of the causes of abutment screw loosening has been identified as inadequate preload. The objective behind this study was to compare the maximum hand-generated torque for tightening abutment screws by professors and postgraduate dental students using a digital torquemeter with 0.1 N/cm precision. In a laboratory study conducted in Dental Implant Department of Faculty of Dentistry, Tabriz University of Medical Sciences, the maximum hand-generated torque for tightening abutment screws by professors and postgraduate dental students was investigated, using a digital torquemeter with 0.1 N/cm precision. The participants consisted of 36 (41.9%) females and 50 (58.1%) males, totaling 86 participants, of whom 45 (46.87%) and 41 (53.13%) were university professors and postgraduate dental students, respectively. The mean age of the participants was 33.4±10.2 years with an age range of 25‒60 years; 50 (58.1%) participants were in the 25‒34-year, 23 (26.7%) in the 35‒47-year, and 13 (15.1%) in the 48‒60-year age range. The mean age of professors and postgraduate dental students was 41±8.3 and 25.1±3.3 years, respectively. The means of maximum torques generated by female and male professors were 14.3±3 and 20.8±4.2, respectively. The means of maximum torques generated by female and male postgraduate dental students were 14.7±3.4 and 18.7±4.3, respectively. Statistical analyses showed no significant differences between the mean maximum torques generated by professors and postgraduate dental students (P=0.051). In the present study, the mean maximum torque generated by professors was higher than that generated by postgraduate dental students. However, the difference was not statistically significant. The mean maximum torque generated by male subjects was significantly higher. No interaction was seen between the studied groups and sex. However, there was a statistically significant difference between the mean maximum torques generated in different age ranges; i.e., the maximum torque generated in the 25‒34-year age range was lower than that in the other two age groups. Finally, the effect of age range on the mean maximum torque was similar in both groups.
牙科种植体的使用频率在不断增加。基台螺钉松动的原因之一已被确定为预紧力不足。本研究的目的是使用精度为0.1 N/cm的数字扭矩计,比较教授和牙科研究生拧紧基台螺钉时的最大手动扭矩。在大不里士医科大学牙科学院种植牙科进行的一项实验室研究中,使用精度为0.1 N/cm的数字扭矩计,研究了教授和牙科研究生拧紧基台螺钉时的最大手动扭矩。参与者包括36名(41.9%)女性和50名(58.1%)男性,共86人,其中45名(46.87%)是大学教授,41名(53.13%)是牙科研究生。参与者的平均年龄为33.4±10.2岁,年龄范围为25至60岁;50名(58.1%)参与者年龄在25至34岁之间,23名(26.7%)在35至47岁之间,13名(15.1%)在48至60岁之间。教授和牙科研究生的平均年龄分别为41±8.3岁和25.1±3.3岁。女性和男性教授产生的最大扭矩平均值分别为14.3±3和20.8±4.2。女性和男性牙科研究生产生的最大扭矩平均值分别为14.7±3.4和18.7±4.3。统计分析表明,教授和牙科研究生产生的平均最大扭矩之间无显著差异(P = 0.051)。在本研究中,教授产生的平均最大扭矩高于牙科研究生产生的平均最大扭矩。然而,差异无统计学意义。男性受试者产生的平均最大扭矩显著更高。研究组与性别之间未发现相互作用。然而,不同年龄范围产生的平均最大扭矩之间存在统计学显著差异;即25至34岁年龄范围产生的最大扭矩低于其他两个年龄组。最后,年龄范围对平均最大扭矩的影响在两组中相似。