Song Hui, Gao Zhong-Yang, Zhao Ying-Jie, Gao Zheng-Chao, Qiu Xiao-Wen, Li Hao-Peng, He Xi-Jing
Department of Orthopaedics, the 2nd Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710004, Shaanxi, China.
Department of Orthopaedics, the 2nd Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710004, Shaanxi, China;
Zhongguo Gu Shang. 2018 Nov 25;31(11):1017-1021. doi: 10.3969/j.issn.1003-0034.2018.08.007.
To investigate the validity of Coda Motion Analysis System for measuring cervical lateral flexion in normal adults in order to explore a new measuring tool for clinical and research practice.
A total of 43 participants were involved in the study. Cervical range of lateral flexion were measured with Coda Motion Analysis System and "gold standard" X-ray simultaneously. The validity and agreement were assessed using the scatter diagram, the Pearson correlation coefficient and limits of agreement.
Cervical range of lateral flexion measured by Coda Motion Analysis System had no statistical differences with those measured by X-ray(>0.05). The Coda Motion Analysis System demonstrated a very good linear relation with the X-ray measurements in cervical range of right lateral flexion, left flexion and total lateral flexion, and the Pearson correlation coefficients were 0.72, 0.85 and 0.90 respectively.
Coda Motion Analysis System showed good validity for measuring cervical lateral flexion in normal adults. Because the reliability of Coda Motion Analysis System was established previously, the results of this study suggest that the system has the potential to be used to measure cervical lateral flexion in clinical and research practice.
探讨Coda运动分析系统测量正常成年人颈椎侧屈的有效性,以探索一种用于临床和研究实践的新型测量工具。
共有43名参与者纳入本研究。使用Coda运动分析系统和“金标准”X线同时测量颈椎侧屈范围。采用散点图、Pearson相关系数和一致性界限评估有效性和一致性。
Coda运动分析系统测量的颈椎侧屈范围与X线测量结果无统计学差异(>0.05)。Coda运动分析系统在颈椎右侧屈、左侧屈和总侧屈范围与X线测量显示出非常好的线性关系,Pearson相关系数分别为0.72、0.85和0.90。
Coda运动分析系统在测量正常成年人颈椎侧屈方面显示出良好的有效性。由于Coda运动分析系统的可靠性先前已得到确立,本研究结果表明该系统有潜力用于临床和研究实践中测量颈椎侧屈。