Suppr超能文献

维纳滤波器提高了核素心肌灌注显像计算机辅助诊断的准确性——与血管造影和CT血管造影的比较。

Wiener filter improves diagnostic accuracy of CAD SPECT images-comparison to angiography and CT angiography.

作者信息

Masoomi Michael A, Al-Shammeri Iman, Kalafallah Khaled, Elrahman Hany M A, Ragab Osama, Ahmed Ebba, Al-Shammeri Jehan, Arafat Sharif

机构信息

Department of Nuclear Medicine and Molecular Imaging, Adan HospitalHadiya, KW.

Department of Nuclear Medicine, Kuwait Cancer Control Centre, Sabah Medical District, Shuwaikh.

出版信息

Medicine (Baltimore). 2019 Jan;98(4):e14207. doi: 10.1097/MD.0000000000014207.

Abstract

Many discrepancy in selection of proper filter and its parameters for individual cases exists. The authors investigate the impact of the most common filters on patient NM images with coronary artery disease (CAD), and compare the results with the computerized tomography (CT)-Angio and angiography for accuracy.The investigation initiated by performing various single photon emission computerized tomography (SPECT)/CT scan of the national electrical manufacturers association chest phantoms having hot and cold inserts. Data acquired on GE 670 PRO SPECT/CT; 360Ø, 64 frames, 60 seconds, low energy high resolution (LEHR) 128, low energy general purpose (LEGP) with CT attenuation (120 kV and 170 mA). The images reconstructed with filtered back projection and ITERATIVE ordered-subset expectation maximization utilizing filters; Hann, Butterworth, Metz, Hamming, and Wiener. The Image contrast was calculated to assess absolute nearness of the inserts. Based on the preliminary results, then scans of 92 patients with CAD; 64 males and 28 females, age 41 to 77 years old, who had been reported earlier reprocessed with the nominated filter and were reported by 2 NM expert. The results compared to the earlier reports and to the CT-Angio and angiography.The optimization suggested 3 filters; Wiener (Wi), Metz and Butterworth (But) provide the highest contrast (99- 66.4%) and (81- 32%) for the cold and hot inserts respectively, with the (Wi) filter to be the better option. The reprocessed patients scan with the (Wi) presented an elevated diagnostic accuracy, correlated well with the CT-Angio and angiography results (P < .001 and r = 0.79 for [Wi] and P = .004 and r = 0.39 for [But]). The percentage of the false negative for moderate to severe CAD cases reported using Wi filter reduced from 27% to 7% and similarly for mild CAD cases from 7% to 1%.It appears the Wiener filter could produce results with the highest contrast for phantom imaging of various cold and hot spheres and for the patient data which is more consistent with angiography results, with much-elevated accuracy in intermediate cases (r = 0.79 for Wiener and r = 0.39 for Butterworth vs angiography). However, the optimum parameters obtained for the filters have no relation with the resolution of the imaging system, but the details of the objects could be improved.

摘要

在为个别病例选择合适的滤波器及其参数方面存在许多差异。作者研究了最常用的滤波器对冠心病(CAD)患者核医学图像的影响,并将结果与计算机断层扫描(CT)血管造影和血管造影的准确性进行比较。该研究首先对具有热插片和冷插片的国家电气制造商协会胸部模型进行各种单光子发射计算机断层扫描(SPECT)/CT扫描。在GE 670 PRO SPECT/CT上采集数据;360°,64帧,60秒,低能高分辨率(LEHR)128,带CT衰减的低能通用型(LEGP)(120 kV和170 mA)。利用Hann、Butterworth、Metz、Hamming和Wiener滤波器通过滤波反投影和迭代有序子集期望最大化重建图像。计算图像对比度以评估插片的绝对接近度。基于初步结果,然后对92例CAD患者进行扫描;64名男性和28名女性,年龄41至77岁,这些患者先前已用指定滤波器重新处理,并由2名核医学专家报告。结果与早期报告以及CT血管造影和血管造影进行比较。优化建议使用3种滤波器;Wiener(Wi)、Metz和Butterworth(But)分别为冷插片和热插片提供最高对比度(99 - 66.4%)和(81 - 32%),其中(Wi)滤波器是更好的选择。用(Wi)重新处理的患者扫描显示诊断准确性提高,与CT血管造影和血管造影结果相关性良好([Wi]的P <.001且r = 0.79,[But]的P =.004且r = 0.39)。使用Wiener滤波器报告的中度至重度CAD病例的假阴性百分比从27%降至7%,轻度CAD病例同样从7%降至1%。似乎Wiener滤波器可以为各种冷球和热球的体模成像以及与血管造影结果更一致的患者数据产生最高对比度的结果,在中间病例中准确性大大提高(Wiener与血管造影的r = 0.79,Butterworth与血管造影的r = 0.39)。然而,为滤波器获得的最佳参数与成像系统的分辨率无关,但可以改善物体的细节。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验