生物定时器检测法作为一种补充方法,与涡旋-超声-涡旋技术联合应用于植入物相关感染的微生物学诊断。

BioTimer assay as complementary method to vortex-sonication-vortex technique for the microbiological diagnosis of implant associated infections.

机构信息

Department of Public Health and Infectious Diseases, University of Rome La Sapienza, Rome, Italy.

出版信息

Sci Rep. 2019 May 17;9(1):7534. doi: 10.1038/s41598-019-44045-1.

Abstract

To enumerate bacteria adherent to medical devices, Vortex-Sonication-Vortex Method (VSVM) and BioTimer Assay (BTA) have been applied. VSVM counts detached microorganisms whereas BTA enumerates adherent microorganisms through microbial metabolism. However, the limitation of VSVM consists in incomplete detachment of adherent microorganisms while BTA is unable to identify microbial genera and species. Herein, the combined use of VSVM and BTA for the diagnosis and enumeration of adherent microorganisms causing implant-associated-infections (IAIs) is reported. Over 2016-2018, 46 patients with IAIs were enrolled and their 82 explanted devices were submitted firstly to VSVM and then to BTA. VSVM plus BTA detected microorganisms in 39/46 patients (84.7%) compared with 32/46 (69.5%) and 31/46 (67.3%) by VSVM and BTA alone, respectively. Likely, combined methods led to microorganism detection in 54/82 devices (65.9%) compared with each method alone [43/82 (52.4%), 44/82 (53.6%) for VSVM and BTA, respectively]. The combination of both methods (concordance 75.6%) raised the sensitivity of microbial analysis in IAIs compared with either VSVM or BTA alone, thus representing a simple and accurate way for the identification and enumeration of microorganisms adherent on devices. Moreover, BTA reagent applied in a new apparatus allowed also the enumeration of the microorganisms adherent on different segments of cardiac electrodes, thus contributing to define IAIs pathogenesis.

摘要

为了枚举黏附在医疗器械上的细菌,已经应用了涡旋-超声-涡旋法(VSVM)和生物计时器检测法(BTA)。VSVM 计数脱落的微生物,而 BTA 通过微生物代谢来计数黏附的微生物。然而,VSVM 的局限性在于它不能完全洗脱黏附的微生物,而 BTA 则无法识别微生物属和种。本文报道了联合应用 VSVM 和 BTA 诊断和计数与植入物相关感染(IAIs)相关的黏附微生物。2016 年至 2018 年,共纳入 46 例 IAI 患者,将他们 82 个已植入的器械首先进行 VSVM 检测,然后进行 BTA 检测。VSVM 加 BTA 检测到 39/46 例(84.7%)患者的微生物,而 VSVM 和 BTA 单独检测到 32/46 例(69.5%)和 31/46 例(67.3%)患者的微生物。同样,联合方法在 54/82 例(65.9%)器械中检测到微生物,而每个单独方法在 43/82 例(52.4%)、44/82 例(53.6%)器械中检测到微生物。与单独使用 VSVM 或 BTA 相比,这两种方法的联合使用(一致性为 75.6%)提高了微生物分析在 IAI 中的敏感性,因此是一种简单而准确的方法,可用于识别和计数黏附在器械上的微生物。此外,BTA 试剂应用于新设备还允许对心脏电极不同部位黏附的微生物进行计数,从而有助于确定 IAI 的发病机制。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8bc6/6525267/592e343c95c1/41598_2019_44045_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验