Suppr超能文献

辐射安全暂停的使用可减少电生理程序中的辐射暴露。

Utilization of a Radiation Safety Time-Out Reduces Radiation Exposure During Electrophysiology Procedures.

机构信息

New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Medical Center, New York, New York.

New York University Cardiac Electrophysiology Service, New York University School of Medicine, New York University Langone Medical Center, New York, New York.

出版信息

JACC Clin Electrophysiol. 2019 May;5(5):626-634. doi: 10.1016/j.jacep.2018.12.002. Epub 2019 Jan 30.

Abstract

OBJECTIVES

This study sought to determine whether a radiation safety time-out reduces radiation exposure in electrophysiology procedures.

BACKGROUND

Time-outs are integral to improving quality and safety. The authors hypothesized that a radiation safety time-out would reduce radiation exposure levels for patients and the health care team members.

METHODS

The study was performed at the New York University Langone Health Electrophysiology Lab. Baseline data were collected for 6 months prior to the time-out. On implementation of the time-out, data were collected prospectively with analyses to be performed every 3 months. The primary endpoint was dose area product. The secondary endpoints included reference point dose, fluoroscopy time, use of additional shielding, and use of alternative imaging such as intracardiac and intravascular ultrasound.

RESULTS

A total of 1,040 patient cases were included. The median dose area product prior to time-out was 18.7 Gy∙cm, and the median during the time-out was 14.7 Gy∙cm, representing a 21% reduction (p = 0.007). The median reference point dose prior to time-out was 163 mGy, and during the time-out was 122 mGy (p = 0.011). The use of sterile disposable protective shields and ultrasound imaging for access increased significantly during the time-out.

CONCLUSIONS

A radiation safety time-out significantly reduces radiation exposure in electrophysiology procedures. Electrophysiology laboratories, as well as other areas of cardiovascular medicine using fluoroscopy, should strongly consider the use of radiation safety time-outs to reduce radiation exposure and improve safety.

摘要

目的

本研究旨在确定辐射安全暂停是否会降低电生理程序中的辐射暴露。

背景

暂停是提高质量和安全性的重要组成部分。作者假设辐射安全暂停将降低患者和医疗保健团队成员的辐射暴露水平。

方法

该研究在纽约大学朗格尼健康电生理实验室进行。在暂停之前收集了 6 个月的基线数据。在实施暂停时,前瞻性地收集数据,并每 3 个月进行一次分析。主要终点是剂量面积产品。次要终点包括参考点剂量、透视时间、额外屏蔽的使用以及替代成像(如心内和血管内超声)的使用。

结果

共纳入 1040 例患者。暂停前的剂量面积产品中位数为 18.7 Gy·cm,暂停期间的中位数为 14.7 Gy·cm,降低了 21%(p=0.007)。暂停前参考点剂量中位数为 163 mGy,暂停期间为 122 mGy(p=0.011)。在暂停期间,无菌一次性防护屏和超声成像用于进入的使用显著增加。

结论

辐射安全暂停可显著降低电生理程序中的辐射暴露。应强烈考虑在电生理实验室以及其他使用透视的心血管医学领域使用辐射安全暂停,以降低辐射暴露并提高安全性。