Suppr超能文献

Langmuir probe electronics upgrade on the tokamak à configuration variable.

作者信息

De Oliveira H, Marmillod P, Theiler C, Chavan R, Février O, Labit B, Lavanchy P, Marlétaz B, Pitts R A

机构信息

Ecole Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.

ITER Organization, Route de Vinon sur Verdon, CS90 046, 13067 St Paul Lez Durance, Cedex, France.

出版信息

Rev Sci Instrum. 2019 Aug;90(8):083502. doi: 10.1063/1.5108876.

Abstract

A detailed description of the Langmuir probe electronics upgrade for TCV (Tokamak à Configuration Variable) is presented. The number of amplifiers and corresponding electronics has been increased from 48 to 120 in order to simultaneously connect all of the 114 Langmuir probes currently mounted in the TCV divertor and main-wall tiles. Another set of 108 amplifiers is ready to be installed in order to connect 80 new probes, built in the frame of the TCV divertor upgrade. Technical details of the amplifier circuitry are discussed as well as improvements over the first generation of amplifiers developed at SPC (formerly CRPP) in 1993/1994 and over the second generation developed in 2012/2013. While the new amplifiers have been operated successfully for over a year, it was found that their silicon power transistors can be damaged during some off-normal plasma events. Possible solutions are discussed.