Multivix Faculty, Vitória, Brazil.
Rio de Janeiro University, Rio de Janeiro, Brazil.
Orthod Craniofac Res. 2020 Feb;23(1):59-65. doi: 10.1111/ocr.12343. Epub 2019 Sep 30.
To verify the correlation between cone beam CT (CBCT) and spiral CT (SCT) images and direct measurement of the bone height and to verify whether bone thickness (BT) influences the accuracy of bone height measurement on CT.
One hundred and fourteen measurements were obtained in 10 dry human mandibles.
The alveolar bone height was measured on volumetric and linear images.
Negative, average and significant correlations (-0.622** to -0.489**) were verified between BT and the absolute error. When the alveolar bone thickness was at least 0.6 mm, the mean differences were 0.16 and 0.28 mm on linear images and 0.12 and 0.03 mm on volumetric images for CBCT and SCT. Additionally, these values ranged from -0.46 to 0.79 and -0.32 to 0.88 mm on linear images and from -0.64 to 0.67 and -0.57 to 0.62 mm on volumetric images for CBCT and SCT. When the alveolar bone thickness was less than 0.6 mm, the CT evaluation varied from -1.74 to 5.42 and -1.64 to 5.42 mm on linear images and from -3.70 to 4.28 mm and -3.49 to 4.25 mm on volumetric images for CBCT and SCT.
Spiral CT and CBCT images demonstrate significant correlation with direct measurement for the alveolar bone height. Measurement of the alveolar bone labial and lingual to the mandibular incisors and canines presented higher accuracy when its thickness was greater than 0.6 mm. When the thickness was less than 0.6 mm, bone dehiscence can be diagnosed despite bone being clinically present.
验证锥形束 CT(CBCT)与螺旋 CT(SCT)图像与直接测量骨高度的相关性,并验证骨厚度(BT)是否会影响 CT 上骨高度测量的准确性。
在 10 个干燥的人下颌骨中获得了 114 次测量。
在容积和线性图像上测量牙槽骨高度。
BT 与绝对误差之间存在负相关、平均相关和显著相关(-0.622** 至-0.489**)。当牙槽骨厚度至少为 0.6mm 时,线性图像上 CBCT 和 SCT 的平均差值分别为 0.16 和 0.28mm,容积图像上分别为 0.12 和 0.03mm。此外,线性图像上这些值的范围为-0.46 至 0.79 和-0.32 至 0.88mm,容积图像上分别为-0.64 至 0.67 和-0.57 至 0.62mm。当牙槽骨厚度小于 0.6mm 时,CT 评估值在线性图像上从-1.74 至 5.42 和-1.64 至 5.42mm 变化,容积图像上从-3.70 至 4.28mm 和-3.49 至 4.25mm 变化。
螺旋 CT 和 CBCT 图像与牙槽骨高度的直接测量具有显著相关性。当厚度大于 0.6mm 时,测量下颌切牙和尖牙唇侧和舌侧的牙槽骨具有更高的准确性。当厚度小于 0.6mm 时,即使临床上存在骨,也可以诊断骨开窗。