Suppr超能文献

市售018Roth和022MBT PEA品牌在上颌前牙区扭矩处方的比较评估

Comparative evaluation of torque prescription of commercially available 018Roth and 022MBT PEA brands in maxillary anterior teeth.

作者信息

Chaudhary Dinesh Chander, Sharma Vineet

机构信息

Graded Specialist (Orthodontics), Air Force Institute of Dental Sciences, Bengaluru 560007, India.

Commandant & Command Dental Adviser, CMDC (NC), India.

出版信息

Med J Armed Forces India. 2019 Oct;75(4):415-423. doi: 10.1016/j.mjafi.2018.03.007. Epub 2018 Oct 11.

Abstract

BACKGROUND

Torque is an important component of preadjusted edgewise prescriptions to achieve ideal/optimum tooth position and more so in aesthetics sensitive maxillary anterior teeth. Thus, the need to audit available commercial brands of 018Roth and 022MBT was felt and in vitro analysis of eight brands namely 3M Unitek, Dentaurum, d-tech, IMD Medical, Libral Leone, Modern Orthodontics, Ormco and Ortho Organizer, was carried out.

METHODS

The method involved perfect superimposition of two standardized images: one delineating facial axis of the tooth with stainless steel straight wire and other with full dimension arch wire engagement in bracket. The two images were superimposed and opacity of one of the images altered using Adobe Photoshop software to reveal the position of two wires. The angle obtained between two wires gave a direct read-out of torque expression. The comparison was statistically done with one-way ANOVA and Tukey's HSD test.

RESULTS

In 018Roth group, IMD Medical did not show any significant difference from the standard while comparison independent of standard showed that IMD, Modern Orthodontics and Ormco were not significantly different from each other. In 022MBT group, IMD Medical, d-tech, 3M Unitek and Modern Orthodontics did not have statistically significant difference from and independent of standard.

CONCLUSION

Significant variations from the standard values of both 018 Roth and 022 MBT exist in the market products and thus selection of product must be based on proper guidance in addition to clinical acumen/experience. Also the methodology provides easy to use, inexpensive set-up in the clinical settings.

摘要

背景

转矩是预成直丝弓矫治处方中实现理想/最佳牙齿位置的重要组成部分,对于美学要求较高的上颌前牙更是如此。因此,人们认为有必要对018Roth和022MBT的现有商业品牌进行评估,并对3M Unitek、Dentaurum、d-tech、IMD Medical、Libral Leone、Modern Orthodontics、Ormco和Ortho Organizer这八个品牌进行了体外分析。

方法

该方法包括完美叠加两张标准化图像:一张用不锈钢直丝描绘牙齿的面部轴,另一张用全尺寸弓丝与托槽的结合。将这两张图像叠加,并使用Adobe Photoshop软件改变其中一张图像的不透明度,以显示两根丝的位置。两根丝之间获得的角度直接显示了转矩表达。使用单向方差分析和Tukey's HSD检验进行统计学比较。

结果

在018Roth组中,IMD Medical与标准值无显著差异,而独立于标准的比较显示,IMD、Modern Orthodontics和Ormco之间无显著差异。在022MBT组中,IMD Medical、d-tech、3M Unitek和Modern Orthodontics与标准值及独立于标准的情况均无统计学显著差异。

结论

市场上的产品与018 Roth和022 MBT的标准值存在显著差异,因此除了临床敏锐度/经验外,产品的选择还必须基于适当的指导。此外,该方法在临床环境中提供了易于使用且成本低廉的设置。

相似文献

1
Comparative evaluation of torque prescription of commercially available 018Roth and 022MBT PEA brands in maxillary anterior teeth.
Med J Armed Forces India. 2019 Oct;75(4):415-423. doi: 10.1016/j.mjafi.2018.03.007. Epub 2018 Oct 11.
2
Are torque values of preadjusted brackets precise?
J Appl Oral Sci. 2011 Aug;19(4):313-7. doi: 10.1590/s1678-77572011005000003. Epub 2011 May 27.
5
Torque value accuracy of preadjusted metal brackets for upper and lower incisors.
Minerva Stomatol. 2019 Feb;68(1):31-35. doi: 10.23736/S0026-4970.18.04148-1.
7
Straight wire: the next generation.
Am J Orthod Dentofacial Orthop. 1993 Jul;104(1):8-20. doi: 10.1016/0889-5406(93)70023-H.
8
Numeric modeling of torque capabilities of self-ligating and conventional brackets.
Am J Orthod Dentofacial Orthop. 2009 Nov;136(5):638-43. doi: 10.1016/j.ajodo.2009.04.018.
9
Effect of dental arch convexity and type of archwire on frictional forces.
Am J Orthod Dentofacial Orthop. 2009 Jul;136(1):14.e1-7; discussion 14-5. doi: 10.1016/j.ajodo.2008.06.026.
10
Frictional resistance between orthodontic brackets and archwire: an in vitro study.
J Contemp Dent Pract. 2011 Mar 1;12(2):91-9. doi: 10.5005/jp-journals-10024-1015.

本文引用的文献

1
Are torque values of preadjusted brackets precise?
J Appl Oral Sci. 2011 Aug;19(4):313-7. doi: 10.1590/s1678-77572011005000003. Epub 2011 May 27.
2
Orthodontics in 3 millennia. Chapter 16: Late 20th-century fixed appliances.
Am J Orthod Dentofacial Orthop. 2008 Dec;134(6):827-30. doi: 10.1016/j.ajodo.2008.04.016.
5
Anterior tooth morphology and its effect on torque.
Eur J Orthod. 2005 Jun;27(3):258-62. doi: 10.1093/ejo/cji007.
6
An evaluation of slot size in orthodontic brackets--are standards as expected?
Angle Orthod. 2004 Aug;74(4):450-3. doi: 10.1043/0003-3219(2004)074<0450:AEOSSI>2.0.CO;2.
7
Physical and mechanical properties affecting torque control.
J Clin Orthod. 2004 Jun;38(6):335-40; quiz 334.
9
Effect of variation in tooth morphology and bracket position on first and third order correction with preadjusted appliances.
Am J Orthod Dentofacial Orthop. 1999 Sep;116(3):329-35. doi: 10.1016/s0889-5406(99)70246-5.
10
Assessment of second-order clearances between orthodontic archwires and bracket slots via the critical contact angle for binding.
Angle Orthod. 1999 Feb;69(1):71-80. doi: 10.1043/0003-3219(1999)069<0071:AOSOCB>2.3.CO;2.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验