Suppr超能文献

双动髋臼杯与非骨水泥三锥度股骨柄组合用于全髋关节置换的长期疗效:一项多中心回顾性分析

Long-term outcomes of a dual-mobility cup and cementless triple-taper femoral stem combination in total hip replacement: a multicenter retrospective analysis.

作者信息

Cypres Alain, Fiquet Arnaud, Girardin Philippe, Fitch David, Bauchu Philippe, Bonnard Olivier, Noyer Daniel, Roy Christophe

机构信息

Clinique du Renaison, 75 Rue Général Giraud, 42300, Roanne, France.

Infirmerie Protestante, Caluire et Cuire, France.

出版信息

J Orthop Surg Res. 2019 Nov 21;14(1):376. doi: 10.1186/s13018-019-1436-y.

Abstract

BACKGROUND

The separate design concepts of dual-mobility cups and triple-taper femoral stems were developed to improve survivorship following total hip replacement (THR) by reducing instability/dislocation and enabling enhanced fixation. Successful outcomes at over two decades have been reported with earlier-generation devices based on these concepts. The current study aimed to provide the first long-term results with a unique pairing of later-generation dual-mobility cup and triple-taper cementless femoral stem after a decade of use in patients undergoing THR.

METHODS

In this retrospective analysis, records were reviewed for all subjects implanted with this dual-mobility cup/cementless femoral stem combination at three centers between 2002 and 2005. Any subject who had not already had follow-up visit beyond 10 years, was not previously revised, and still living were invited for a single follow-up visit consisting of Merle d'Aubgine Scores, the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index, and standard radiographs.

RESULTS

There were 244 THRs available for analysis. At a mean follow-up of 11.9 years, the Kaplan-Meier survivorship (endpoint: revision for any reason) was 99.1% (95% CI, 97.6-99.7) for the stem and 95.9% (95% CI, 93.1-97.6) for the cup. Merle d'Aubigne Scores were significantly improved from baseline and WOMAC scores were in the satisfactory range at the final follow-up. Radiographic analysis revealed no cases of stem subsidence, no cases of bone hypertrophy, 1 (0.4%) case of bone atrophy, and 3 (1.2%) cases of osteolysis around the stem. No subjects had radiolucent lines greater than 1 mm in any femoral Gruen zone. Evidence of cup migration was seen in 1 (0.4%) subject and 1 (0.4%) subject had evidence of osteolysis that was seen in Gruen zones I, II, IV, and V.

CONCLUSIONS

This combination of a later-generation dual-mobility cup and cementless triple-taper stem was associated with excellent survivorship and satisfactory functional outcomes at over 10 years follow-up.

TRIAL REGISTRATION

ClinicalTrials.gov, NCT02648152. Date of registration: January 6, 2016. Retrospectively registered.

摘要

背景

双动髋臼杯和三锥度股骨柄的独立设计理念旨在通过减少不稳定/脱位并实现更强的固定来提高全髋关节置换术(THR)后的生存率。基于这些理念的早期一代器械已有超过二十年的成功应用报道。本研究旨在提供在接受THR的患者中使用了十年的新一代双动髋臼杯和三锥度无骨水泥股骨柄独特组合的首个长期结果。

方法

在这项回顾性分析中,对2002年至2005年间在三个中心植入这种双动髋臼杯/无骨水泥股骨柄组合的所有受试者的记录进行了审查。邀请任何尚未进行超过10年随访、未曾翻修且仍在世的受试者进行一次随访,随访内容包括Merle d'Aubgine评分、西安大略和麦克马斯特大学骨关节炎指数(WOMAC)以及标准X线片。

结果

有244例THR可供分析。平均随访11.9年时,股骨柄的Kaplan-Meier生存率(终点:因任何原因翻修)为99.1%(95%CI,97.6 - 99.7),髋臼杯为95.9%(95%CI,93.1 - 97.6)。Merle d'Aubigne评分较基线显著改善,最终随访时WOMAC评分处于满意范围。影像学分析显示无股骨柄下沉病例,无骨质增生病例,1例(0.4%)骨质萎缩病例,以及3例(1.2%)股骨柄周围骨溶解病例。在任何股骨Gruen区均无大于1mm的透亮线。在1例(0.4%)受试者中可见髋臼杯移位证据,1例(0.4%)受试者有在Gruen区I、II、IV和V可见的骨溶解证据。

结论

在超过10年的随访中,这种新一代双动髋臼杯和无骨水泥三锥度股骨柄的组合具有出色的生存率和令人满意的功能结果。

试验注册

ClinicalTrials.gov,NCT02648152。注册日期:2016年1月6日。回顾性注册。